Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 604110 R10418A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Viscosity Improvers
Uses advised against
None identified.
Manufacturers & Suppliers
LUBRIZOL FRANCE
manufacturer
25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173 FR
(33) 02.35.58.14.00
http://www.mylubrizol.com
Emergency Contacts
CHEMTREC
(+1) 703 527 3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2,6-Di-tert-butyl-p-cresol EC: 204-881-4 | --- | 0.1 - 0.25% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove exposed person to fresh air if adverse effects are observed.
Wash with soap and water. Launder contaminated clothing before reuse.
Any material that contacts the eye should be washed out immediately with water. If easy to do, remove contact lenses.
Treat symptomatically.
Immediate Medical Attention
Get medical attention if symptoms occur (Skin Contact). Get medical attention (Ingestion).
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.
Do not use water jet as an extinguisher, as this will spread the fire.
Material creates a special hazard because it floats on water. See section 10 for additional information.
No data available.
Firefighter Protection
Recommend wearing self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dike far ahead of larger spill for later recovery and disposal.
Avoid release to the environment. Prevent further leakage or spillage if safe to do so.
Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material. In case of spills, beware of slippery floors and surfaces. Wear appropriate personal protective equipment.
Store away from incompatible materials. See section 10 for incompatible materials.
Observe good industrial hygiene practices.
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. Nitrile. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.
If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.
Use disposable dust/mist mask if the recommended exposure limit is exceeded. Consult with an industrial hygienist to determine the appropriate respiratory protection for your specific use of this material. A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.
In case of skin contact, wash hands and arms with soap and water.
No data available. See section 6 for details.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
No data available.
Will not occur.
excessive heat, ignition sources
oxidizing materials
Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, and other products of incomplete combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Ecotoxicity
12.1 Ecotoxicity
12.2 Persistence and Degradability
12.2 Persistence and degradability
12.3 Bioaccumulative Potential
12.3 Bioaccumulative potential
12.4 Mobility
12.5 Results of PBT and vPvB assessment
12.6 Other Adverse Effects
No data available.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.
Since emptied containers retain product residue, follow label warnings even after container is emptied.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
All components are in compliance with chemical notification requirements in Australia, Canada, China, Japan, Korea, New Zealand, Philippines, Switzerland, Taiwan, and the United States.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 604110 R10418A?
The signal word is no signal word.
What is the physical form of 604110 R10418A?
604110 R10418A is a liquid appearing as hazy with hazy color. It has mild odor.
What is 604110 R10418A used for?
Viscosity Improvers