NextSDS Logo
Safety Data Sheet EN

GENOMER $ ^{*} $ 5695

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GENOMER $ ^{*} $ 5695

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Resin for radically curable inks, coatings, adhesives, fillers, etc. For industrial use only

Uses advised against

No information available

Manufacturers & Suppliers

R

RAHN AG

undefined

Dörflistrasse 120 8050 Zürich Switzerland

+41 44 315 42 00

Emergency Contacts

Tox Info Suisse

+41 44 251 51 51

24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects

Precautionary Statements

P273 Avoid release to the environment
P501 Dispose of contents/container in accordance with local, regional, national, and international regulations as applicable

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

This product does not contain candidate substances of very high concern at a concentration ≥0.1% (Regulation (EC) No. 1907/2006 (REACH), Article 59)

Chemical Name CAS Number Concentration Hazardous
N/A --- 90 - 95% No
N/A --- 1 - 5% Yes

Notes

Full text of H- and EUH-phrases: see section 16 Acute Toxicity Estimate See chapter 11.1

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air.

Skin contact

Avoid contact with UV and sunlight.

Eye contact

Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Consult a doctor.

Ingestion

Clean mouth with water and drink afterwards plenty of water.

Immediate Medical Attention

Treat symptomatically.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. For small fires: Dry chemical, CO2 or water spray. For large fires: Alcohol resistant foam, Water spray.

Unsuitable media

Full water jet.

Specific hazards

No information available.

Firefighter Protection

Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Use personal protection recommended in Section 8.

Environmental

Do not flush into surface water or sanitary sewer system. See Section 12 for additional Ecological Information.

Cleanup methods

Take up mechanically, placing in appropriate containers for disposal.

Related Substances

Similar chemicals with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure adequate ventilation.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place. Keep out of the reach of children. Store locked up. Do not store at temperatures above 40 °C (104 °F). Keep away from heat. Protect from sunlight. Store in a well-ventilated place.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

Fire prevention

Keep away from heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gloves should be replaced regularly and if there is any sign of damage to the glove material. Wear suitable gloves. Nitrile rubber.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.

Skin/Body

Wear suitable protective clothing.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
No data available
Odor Threshold
---
Evaporation Rate
---
Crystallisation Point
---
Decomposition Temperature
No data available
Physical State Data
liquid
Relative Evaporation Rate
---
Colour Intensity
---
Cloud Point
---
Odor
Ester-like
Solubility In Water
<1 g/l
Softening Point
---
Bulk Density
No data available
Vapor Pressure
No data available
Solubility In Fat
---
Explosive Limits
---
Relative Density
1.12 @ 20°C
Melting Point
No data available
Vapor Density
No data available
Properties Status
---
State Under Standard Conditions
---
Molecular Weight
---
Metal Corrosion
---
Auto Ignition Temperature
No information available
Density
No data available
Solidification Point
---
Flash Point
> 100 °C
Physical State
Liquid
Colour
light yellow
Dynamic Viscosity
3000 - 10'000 mPas @ 25°C
Ph
No data available
Lower Explosive Limit
No data available
Kinematic Viscosity
No data available
Freezing Point
No data available
Voc Content
---
Partition Coefficient
No data available
Flammability
No data available
Form
---
Appearance
---
Upper Explosive Limit
No data available
Solubility
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No information available.

Hazardous reactions

No known hazardous reactions.

Avoid

Keep away from sources of ignition - No smoking. Polymerization occurs when exposed to white light, ultraviolet light or heat. UV-radiation/sunlight.

Incompatible

Avoid contact with radical forming initiators, peroxides, strong alkalis or reactive metals to prevent exothermic polymerization.

Decomposition

None known based on information supplied.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not regulated
Shipping Name
Not regulated
Transport Class
Not regulated
Packing Group
Not regulated
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GENOMER $ ^{*} $ 5695?

The signal word is no signal word.

What is the physical form of GENOMER $ ^{*} $ 5695?

GENOMER $ ^{*} $ 5695 is a liquid with light yellow color. It has ester-like odor.

What is the solubility of GENOMER $ ^{*} $ 5695?

No data available

What is GENOMER $ ^{*} $ 5695 used for?

Resin for radically curable inks, coatings, adhesives, fillers, etc. For industrial use only

What are the hazard statements for GENOMER $ ^{*} $ 5695?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects

What is the melting point of GENOMER $ ^{*} $ 5695?

The melting point is No data available and the boiling point is No data available.

Compliance Scan

Free compliance check