NextSDS Logo
Safety Data Sheet EN

SYNESSTIC™ 5

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SYNESSTIC™ 5
Product Form
Synthetic Base Stock

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Distribution of substance, Formulation and (re)packing of substances and mixtures, Lubricants - Industrial, Metal working fluids / rolling oils - Industrial, Functional Fluids - Industrial, Lubricants - Professional (Low Release), Lubricants - Professional (High Release), Metal working fluids / rolling oils - Professional, Functional Fluids - Professional, Use in Cleaning Agents - Consumer, Lubricants - Consumer (Low Release), Lubricants - Consumer (High Release), Functional Fluids - Consumer

Uses advised against

None unless specified elsewhere in this SDS.

Manufacturers & Suppliers

E

ExxonMobil Petroleum & Chemical BV on behalf of MOBIL CHEMICAL PRODUCTS INTERNATIONAL INC.

national supplier

HERMESLAAN 2, B-1831 MACHELEN, Belgium

+32-2-239 3111

Emergency Contacts

CHEMTREC

+(44)-8708200418

National Poison Control Centre

111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

No Hazardous Substance(s) required for disclosure.

Notes

Not Applicable. This material is regulated as a mixture.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness

Skin contact

Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

Symptoms: Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injection.

Eye contact

Flush thoroughly with water. If irritation occurs, get medical assistance.

Symptoms: irritation

Ingestion

First aid is normally not required. Seek medical attention if discomfort occurs.

Immediate Medical Attention

If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Medical Treatment

early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable media

Straight streams of water

Specific hazards

Incomplete combustion products, Oxides of carbon, Smoke, Fume

Instructions

Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop leak if you can do so without risk.

Large spill

Dyke far ahead of liquid spill for later recovery and disposal.

Environmental

Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.

Materials: dry earth, sand or other non-combustible material, suitable absorbents

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent small spills and leakage to avoid slip hazard. Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures.

Storage

The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or earthing procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

No protection is ordinarily required under normal conditions of use.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

No protection is ordinarily required under normal conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Skin/Body

No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Voc Content
---
Ph
No data available
Physical State Data
liquid
Decomposition Temperature
No data available
Appearance
---
Colour Intensity
---
Solubility
water Negligible
Melting Point
No data available
Bulk Density
---
Cloud Point
---
Solubility In Water
Negligible
Odor
Mild
Upper Explosive Limit
No data available
Flammability
Not technically feasible
Relative Density
0.9 (at 15.6 °C)
Vapor Pressure
< 0 kPa (0 mm Hg) at 25°C
Form
---
Vapor Density
No data available
Explosive Limits
---
Crystallisation Point
---
Colour
Amber
Flash Point
185°C (365°F)
Physical State
Liquid
Evaporation Rate
No data available
Density
---
Freezing Point
No data available
State Under Standard Conditions
---
Molecular Weight
---
Boiling Point
>300°C (572°F)
Solubility In Fat
---
Relative Evaporation Rate
---
Metal Corrosion
---
Dynamic Viscosity
---
Softening Point
---
Auto Ignition Temperature
>400°C (752°F)
Kinematic Viscosity
29 cSt (29 mm2/sec) at 40°C | 4.7 cSt (4.7 mm2/sec) at 100°C
Solidification Point
---
Properties Status
---
Odor Threshold
No data available
Lower Explosive Limit
No data available
Partition Coefficient
11
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

See sub-sections below.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Excessive heat. High energy sources of ignition.

Incompatible

Strong oxidisers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

Disposal

Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal.

Waste Codes

13 02 06* EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Listed or exempt from listing/notification on the following chemical inventories : AIIC, DSL, ENCS, IECSC, ISHL, KECI, PICCS, TCSI, TSCA

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SYNESSTIC™ 5?

The signal word is no signal word.

What is the physical form of SYNESSTIC™ 5?

SYNESSTIC™ 5 is a liquid with amber color. It has mild odor.

What is the solubility of SYNESSTIC™ 5?

water Negligible

What is SYNESSTIC™ 5 used for?

Distribution of substance, Formulation and (re)packing of substances and mixtures, Lubricants - Industrial, Metal working fluids / rolling oils - Industrial, Functional Fluids - Industrial, Lubricants - Professional (Low Release), Lubricants - Professional (High Release), Metal working fluids / rolling oils - Professional, Functional Fluids - Professional, Use in Cleaning Agents - Consumer, Lubricants - Consumer (Low Release), Lubricants - Consumer (High Release), Functional Fluids - Consumer

What is the melting point of SYNESSTIC™ 5?

The melting point is No data available and the boiling point is >300°C (572°F).