Product Information

Product Name
SENTRON™ MG CG 40
Product Code
STLCGJ20, STLCGIBC, STLCGDRX, STLCGDRM, STLCGDCT, STLCG, STLCGBLK

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Sentron oils are designed for use in stationary, spark-ignition, natural gas fuelled engines.

Manufacturers & Suppliers

P

Petro-Canada Europe Lubricants Limited

manufacturer

Wellington House, Starley Way Birmingham International Park Solihull B37 7HB United Kingdom

Emergency Contacts

Petro-Canada Lubricants Inc.

+1 905-403-5770

CHEMTREC

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 50 - 70% Yes
Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased EC: 272-234-3 68784-26-9 1 - 2.5% Yes
Amines, polyethylenepoly-, reaction products with succinic anhydride polyisobutenyl derivs. EC: 617-593-2 84605-20-9 1 - 2.5% Yes
lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based EC: 276-737-9 72623-86-0 1 - 10% Yes
Calcium long chain alkaryl sulfonate 722503-68-6 0.25 - 1% Yes
phenol, dodecyl-, branched EC: 310-154-3 121158-58-5 0.1 - 0.25% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Artificial respiration and/or oxygen may be necessary. Seek medical advice.

Skin contact

In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognized skin cleanser. Wash clothing before reuse. Seek medical advice.

Eye contact

Remove contact lenses. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Obtain medical attention.

Ingestion

Rinse mouth with water. DO NOT induce vomiting unless directed to do so by a physician or poison control center. Never give anything by mouth to an unconscious person. Seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

No information available.

Specific hazards

Cool closed containers exposed to fire with water spray.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas. Mark the contaminated area with signs and prevent access to unauthorized personnel. Only qualified personnel equipped with suitable protective equipment may intervene.

Environmental

Do not allow uncontrolled discharge of product into the environment.

Cleanup methods

Prevent further leakage or spillage if safe to do so. Remove all sources of ignition. Soak up with inert absorbent material. Non-sparking tools should be used. Ensure adequate ventilation. Contact the proper local authorities.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Use only with adequate ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Avoid contact with skin, eyes and clothing. Do not ingest. Keep away from heat and sources of ignition. Keep container closed when not in use.

Storage

Store in original container. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Keep in a dry, cool and well-ventilated place. Keep in properly labelled containers. To maintain product quality, do not store in heat or direct sunlight.

Hygiene

Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash face, hands and any exposed skin thoroughly after handling.

Fire prevention

None known. Keep away from heat and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Material : neoprene, nitrile, polyvinyl alcohol (PVA), Viton(R). Remarks : Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.

Eyes

Wear face-shield and protective suit for abnormal processing problems.

Respiratory

Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Filter type : organic vapour filter

Skin/Body

Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
No data available
State Under Standard Conditions
---
Crystallisation Point
---
Upper Explosive Limit
No data available
Solubility In Fat
---
Ph
No data available
Physical State Data
liquid
Solubility
---
Colour
Yellow or light amber.
Relative Evaporation Rate
---
Molecular Weight
---
Lower Explosive Limit
No data available
Relative Density
No data available
Boiling Point
No data available
Colour Intensity
---
Dynamic Viscosity
---
Solubility In Water
insoluble
Freezing Point
-27 °C (-17 °F)
Evaporation Rate
No data available
Flash Point
273 °C (523 °F)
Melting Point
---
Density
0.8772 kg/l (15 °C / 59 °F)
Form
---
Solidification Point
---
Kinematic Viscosity
125.8 cSt (40 °C / 104 °F) 13.5 cSt (100 °C / 212 °F)
Vapor Density
---
Explosive Limits
---
Odor
Mild petroleum oil like.
Odor Threshold
No data available
Voc Content
---
Decomposition Temperature
---
Appearance
viscous liquid
Properties Status
---
Cloud Point
---
Softening Point
---
Auto Ignition Temperature
No data available
Physical State
viscous liquid
Bulk Density
---
Metal Corrosion
---
Partition Coefficient
No data available
Flammability
Low fire hazard. This material must be heated before ignition will occur.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Hazardous reactions

Hazardous polymerisation does not occur. Stable under normal conditions.

Avoid

No data available

Incompatible

Reactive with oxidising agents, reducing agents and acids.

Decomposition

May release COx, SiOx, H2S, alkyl mercaptans, aldehydes, methacrylate monomers, smoke and irritating vapours when heated to decomposition.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SENTRON™ MG CG 40?

The signal word is no signal word.

What is the physical form of SENTRON™ MG CG 40?

SENTRON™ MG CG 40 is a viscous liquid appearing as viscous liquid with yellow or light amber. color. It has mild petroleum oil like. odor.

What is SENTRON™ MG CG 40 used for?

Sentron oils are designed for use in stationary, spark-ignition, natural gas fuelled engines.

Compliance Scanner

Scan your compliance