Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TRIAMEEN Y12
- Chemical Name
- TRIAMEEN Y12
Regulatory Identifiers
- CAS Number
- 2372-82-9 Check regulations →
- REACH No.
- 01-2119980592-29-0000
Identified Uses
Refer to attached exposure scenario Annex.
Manufacturers & Suppliers
Nouryon Surface Chemistry AB
manufacturer
PO BOX 47067, SE 40258 Goteborg, Sweden
+4630385000
Emergency Contacts
Kemiakuten
020 99 60 00
24 hours emergency response number
+31 57 06 79 211
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Substance name: TRIAMEEN Y12 CAS-No.: 2372-82-9
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N-(3-aminopropyl)-N-dodecylpropane-1,3,diamine EC: 219-145-8 | 2372-82-9 | 90 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. Consult a physician after significant exposure.
Take off contaminated clothing and shoes immediately. Rinse immediately with plenty of water. Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty.
Rinse with plenty of water. Get medical attention immediately. Continue to rinse during transport. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing.
Symptoms: Small amounts splashed into eyes can cause irreversible tissue damage and blindness.
Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person. Take victim immediately to hospital. Do not induce vomiting!
Symptoms: May cause chemical burns in mouth and throat.
Immediate Medical Attention
Immediate medical attention is required. Take victim immediately to hospital.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Do not allow run-off from fire fighting to enter drains or water courses.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate personnel to safe areas. Only qualified personnel equipped with suitable protective equipment may intervene. Prevent unauthorised persons entering the zone.
Discharge into the environment must be avoided.
Soak up with inert absorbent material.
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For personal protection see section 8. Avoid formation of aerosol. Do not breathe vapours or spray mist. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.
Prevent unauthorized access. Keep container tightly closed in a dry and well-ventilated place. Reacts with copper, aluminium, zinc and their alloys.
Avoid contact with skin, eyes and clothing. When using do not eat or drink. When using do not smoke. Wash hands before breaks and immediately after handling the product.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Effective exhaust ventilation system. Ensure that eyewash stations and safety showers are close to the workstation location.
Material: Nitrile rubber; Material: butyl-rubber
Tightly fitting safety goggles. Wear face-shield and protective suit for abnormal processing problems.
In the case of vapour or aerosol formation use a respirator with an approved filter. Wear full face mask supplied with: Combination filter: ABEKP.
Protective suit
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
Extremes of temperature and direct sunlight.
None known.
No hazardous decomposition products are known. Thermal decomposition : No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of contents/container in accordance with local regulation.
The product should not be allowed to enter drains, water courses or the soil. Do not contaminate ponds, waterways or ditches with chemical or used container.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2922
- Shipping Name
- CORROSIVE LIQUID, TOXIC, N.O.S. (Dodecyl dipropylene triamine)
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TRIAMEEN Y12?
The signal word is danger.
What is the physical form of TRIAMEEN Y12?
TRIAMEEN Y12 is a liquid with yellow color. It has ammoniacal odor.
What is the solubility of TRIAMEEN Y12?
soluble
What is TRIAMEEN Y12 used for?
Refer to attached exposure scenario Annex.
What are the hazard statements for TRIAMEEN Y12?
This substance has 4 hazard statements:
- H301: Toxic if swallowed.
- H314: Causes severe skin burns and eye damage.
- H373: May cause damage to organs (Kidney) through prolonged or repeated exposure.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of TRIAMEEN Y12?
The melting point is ca. 7,5 °C and the boiling point is > 200 °C.