NextSDS Logo
TE

TECTYL 900

NO SIGNAL WORD Oily liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
TECTYL 900
Product Code
3022

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Corrosion Preventive Compound

Overview

TECTYL 900 commonly used corrosion preventive compound.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Daubert Chemical Company

undefined

๐Ÿ“

4700 S. Central Avenue Chicago, IL 60638

๐ŸŒ

US

๐Ÿ“ž

708-496-7350

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemtrec

๐Ÿ“ž

(800) 424-9300

๐ŸŒ

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Not hazardous under OSHA regulations.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If symptoms are experienced remove source of contamination or move victim to fresh air and obtain medical advice.

๐Ÿ–๏ธ Skin Contact

Wash with soap and water. Remove contaminated clothing and launder. Get medical attention if irritation develops or persists.

Symptoms:

irritation

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water for at least 20 minutes retracting eyelids often. Tilt the head to prevent chemical from transferring to the uncontaminated eye. Get immediate medical attention and monitor the eye daily as advised by your physician.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting. Seek medical attention immediately. Provide medical care provider with this SDS.

๐Ÿšจ Immediate Medical Attention Required

obtain medical advice (for inhalation). Get immediate medical attention (for eyes). Get medical attention if irritation develops or persists (for skin). Seek medical attention immediately (for ingestion).

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Oily liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Amber
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Slight Solvent Odor
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
225 F( 107 C)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
>1 (n-Butyl Acetate=1)
๐Ÿ’จ Vapor Pressure
< 1 mmHg
๐Ÿ“Š Vapor Density
>1 (Air=1)
๐Ÿ“Š Relative Density
0.88
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
Negligible; 0-1%
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
11 cSt @ 40C
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Local exhaust ventilation or other engineering controls are normally required when handling or using this product to avoid overexposure. Engineering controls must be designed to meet the OSHA chemical specific standard in 29 CFR 1910. Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne levels below recommended exposure limits

๐Ÿงค Hand Protection

Wear protective gloves. Inspect gloves for chemical break-through and replace at regular intervals. Chemically resistant gloves

๐Ÿ‘๏ธ Eye Protection

Wear chemically resistant safety glasses with side shields when handling this product. Do not wear contact lenses.

๐Ÿ˜ท Respiratory Protection

Respiratory protection may be required to avoid overexposure when handling this product. General or local exhaust ventilation is the preferred means of protection. Use a respirator if general room ventilation is not available or sufficient to eliminate symptoms. Follow a respiratory protection program that meets 29 CFR 1910.134 and ANSI Z88.2 requirements whenever work place conditions warrant the use of a respirator.

๐Ÿฆบ Skin/Body Protection

When handling material that has been heated, wear chemical resistant apron, long sleeves and other clothing as necessary to protect against thermal burns.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿ“ฆ Proper Shipping Name

Corrosion Inhibitor - Non-Hazardous

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for TECTYL 900?

The signal word for this substance is "no signal word".

What is the physical form of TECTYL 900?

TECTYL 900 is a oily liquid with amber color. It has slight solvent odor odor.

What is TECTYL 900 used for?

Corrosion Preventive Compound

What is the melting point of TECTYL 900?

The melting point is No data available and the boiling point is No data available.