Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Armand solution
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
In vitro diagnostic medical device. For professional use only.
Manufacturers & Suppliers
RAL DIAGNOSTICS S.A.S.
manufacturer
Site Montesquieu, 33651 MARTILLAC CEDEX France
+33 (0) 5 57 96 04 04
http://www.ral-diagnostics.com
Emergency Contacts
ORFILA
+33 (0) 1 45 42 59 59
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Take victim to fresh air. Obtain medical attention if breathing difficulty persists.
Symptoms: Sore throat. Corrosive to respiratory system.
Wash skin thoroughly with mild soap and water. Seek medical attention immediately.
Symptoms: Redness, pain. Causes burns. Repeated exposure to this material can result in absorption through skin causing significant health hazard.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Symptoms: Blurred vision. Redness, pain. Burning sensation.
Rinse mouth. Do not induce vomiting because of corrosive effects. Call a physician immediately.
Symptoms: Harmful if swallowed. Abdominal pain, nausea. Burning sensation. Must not come into contact with food or be consumed.
Immediate Medical Attention
Seek medical attention immediately (skin), seek medical advice (eyes), call a physician immediately (ingestion).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Powder. Carbon dioxide. Use extinguishing media appropriate for surrounding fire.
No significant hazards.
Exercise caution when fighting any chemical fire. Keep away from sources of ignition. No smoking.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Prevent entry to sewers and public waters.
Clean up any spills as soon as possible
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid all unnecessary exposure. Store and handle as though always a serious potential fire/explosion and health hazard exists. Keep away from sources of ignition - No Smoking. Handle in accordance with appropriate industrial hygiene and safety procedures. Keep away from food, drink and animal feeding stuffs.
Store in dry, cool, well-ventilated area. Keep container closed when not in use. Keep away from heat. Do not store in corrodable metal.
Wash hands and other exposed areas with mild soap and water before eat, drink or smoke and when leaving work.
Keep away from sources of ignition - No Smoking. Keep away from heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide local exhaust or general room ventilation to minimize dust and/or vapour concentrations.
Gloves. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. In full: Material: nitrile rubber. Minimum thickness: 0.56 mm. Break through time: Not tested. Proposed equipment : SOL-VEX® (Ansell 37-185). In the event of splashes: Material: nitrile rubber. Minimum thickness: 0.10 mm. Break through time: Not tested. Proposed equipment : Touch N Tuff® (Ansell 92-500 ou 92-670).
Safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Suitable respiratory equipment. Use a full-face cartridge combination (U.S.) or type ABEK (EN 14387). Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Wear proper protective equipment. Choose body protection in relation to the dangerousness of the product, its concentration and the amounts used depending on the workstation.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable in normal temperature and pressure conditions.
No data available.
No data available.
No data available.
Metals.
No data available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2920
- Shipping Name
- CORROSIVE LIQUID, FLAMMABLE, N.O.S. (Ethanol, Nitric acid)
- Transport Class
- 8, 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Armand solution?
The signal word is danger.
What is the physical form of Armand solution?
Armand solution is a liquid. with dark blue. color. It has characteristic. odor.
What is Armand solution used for?
In vitro diagnostic medical device. For professional use only.
What are the hazard statements for Armand solution?
This substance has 6 hazard statements:
- H226: Flammable liquid and vapour
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H341: Suspected of causing genetic defects.
- H351: Suspected of causing cancer.
- H372: Causes damage to organs through prolonged or repeated exposure.