Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- XENUM C1200+
- Product Form
- Grease
- Product Code
- 4052500
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, PC24 Lubricants, greases, release products, PROC7 Industrial spraying, PROC11 Non industrial spraying
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
XENUM N.V.
manufacturer
Steenkaastraat 17, B-9200 Dendermonde, Belgium
+32 52 22 38 08
Emergency Contacts
Emergency Contact
+32 479 82 08 08
During normal opening hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Active substance with propellant
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| butane (containing < 0.1% butadiene (203-450-8)) EC: 203-448-7 | 106-97-8 | 25 - 50% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 10 - 25% | Yes |
| Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane EC: 921-024-6 | --- | 10 - 25% | Yes |
| Alkylated Diphenylamines | 68411-46-1 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
Do not induce vomiting; call for medical help immediately.
Immediate Medical Attention
call for medical help immediately
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water haze, Fire-extinguishing powder, Carbon dioxide, Alcohol resistant foam
Water with full jet
No further relevant information available.
Firefighter Protection
Mount respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/ surface or ground water.
Do not flush with water or aqueous cleansing agents
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Open and handle receptacle with care.
Store in a cool location. Observe official regulations on storing packagings with pressurised containers. Keep receptacle tightly sealed. Do not seal receptacle gas tight. Store in cool, dry conditions in well sealed receptacles. Protect from heat and direct sunlight.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves, Solvent resistant gloves, Wear gloves for the protection against chemicals according to EN 374. Material: Nitrile rubber, NBR. Recommended thickness: ≥ 0.5 mm. Breakthrough time: For continuous contact we recommend gloves with breakthrough time of at least 240 minutes, with the preference given to a breakthrough time greater than 480 minutes. For short-term or splash guard we recommend the same.
Safety glasses
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Filter AX/P2. Use suitable respiratory protective device in case of insufficient ventilation. Filter A/P2
Use protective suit.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Void
Warning: Gases.
Warning: Gases.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for XENUM C1200+?
The signal word is danger.
What is the physical form of XENUM C1200+?
XENUM C1200+ is a aerosol appearing as form: aerosol colour: according to product specification with according to product specification color. It has characteristic odor.
What is the solubility of XENUM C1200+?
Not miscible or difficult to mix.
What is XENUM C1200+ used for?
SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, PC24 Lubricants, greases, release products, PROC7 Industrial spraying, PROC11 Non industrial spraying
What are the hazard statements for XENUM C1200+?
This substance has 4 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of XENUM C1200+?