Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- R-22
- Chemical Name
- Chlorodifluoromethane
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Refrigerant Gas
Manufacturers & Suppliers
National Refrigerants, Inc.
distributor
661 Kenyon Avenue, Bridgeton, New Jersey 08302
1-800-262-0012
Emergency Contacts
CHEMTREC
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Chlorodifluoromethane | 75-45-6 | 100% | No |
Notes
There are no impurities or stabilizers that contribute to the classification of the material identified in Section 2
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately remove to fresh air. If breathing has stopped, give artificial respiration. Use oxygen as required, provided a qualified operator is available. Get medical attention immediately. DO NOT give epinephrine (adrenaline).
Promptly flush skin with water until all chemical is removed. If there is evidence of frostbite, bathe (do not rub) with lukewarm (not hot) water. If water is not available, cover with a clean, soft cloth or similar covering. Get medical attention if symptoms persist.
Symptoms: frostbite
Immediately flush eyes with large amounts of water for at least 15 minutes (in case of frostbite, water should be lukewarm, not hot) lifting eyelids occasionally to facilitate irrigation. Get medical attention if symptoms persist.
Ingestion is unlikely because of the physical properties and is not expected to be hazardous. DO NOT induce vomiting unless instructed to do so by a physician.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treatment of overexposure should be directed at the control of symptoms and the clinical conditions.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use any standard agent – choose the one most appropriate for type of surrounding fire (material itself is not flammable)
R-22 is not flammable at ambient temperatures and atmospheric pressure. However, this material will become combustible when mixed with air under pressure and exposed to strong ignition sources. Contact with certain reactive metals may result in formation of explosive or exothermic reactions under specific conditions (e.g. very high temperatures and/or appropriate pressures).
Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Firefighters should wear self-contained, NIOSH-approved breathing apparatus for protection against possible toxic decomposition products. Proper eye and skin protection should be provided.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unprotected personnel. Product dissipates upon release. Protected personnel should remove ignition sources and shut off leak, if without risk, and provide ventilation. Unprotected personnel should not return to the affected area until air has been tested and determined safe, including low-lying areas.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always wear recommended personal protective equipment. Avoid breathing vapors and liquid contact with eyes, skin or clothing. Do not puncture or drop cylinders, expose them to open flame or excessive heat. Use authorized cylinders only. Follow standard safety precautions for handling and use of compressed gas cylinders.
Store in a cool, well-ventilated area of low fire risk and out of direct sunlight. Protect cylinder and its fittings from physical damage. Storage in subsurface locations should be avoided. Close valve tightly after use and when empty.
Always wear recommended personal protective equipment.
Do not expose to open flame or excessive heat. R-22 should not be mixed with air above atmospheric pressure for leak testing or any other purpose.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide local ventilation at filling zones and areas where leakage is probable. Mechanical (general) ventilation may be adequate for other operating and storage areas.
General work clothing and gloves (leather) should provide adequate protection. If prolonged contact with liquid or gas is anticipated, insulated gloves constructed of PVA, neoprene or butyl rubber should be used.
For normal conditions, wear safety glasses. Where there is reasonable probability of liquid contact, wear chemical safety goggles.
None generally required for adequately ventilated work situations. For accidental release or non-ventilated situations, or release into confined space, where the concentration may be above the PEL of 1,000 ppm, use a self-contained, NIOSH approved breathing apparatus or supplied air respirator. For escape: use the former or a NIOSH approved gas mask with organic vapor canister.
Skin contact with refrigerant may cause frostbite. General work clothing. Where contact with liquid is likely, such as in a spill or leak, impervious boots and clothing should be worn.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
Will not occur
Do not mix with oxygen or air above atmospheric pressure. Any source of high temperatures, such as lighted cigarettes, flames, hot spots or welding may yield toxic and/or corrosive decomposition products.
Freshly abraded aluminum surfaces (may cause strong exothermic reaction). Chemically reactive metals: potassium, calcium, powdered aluminum, magnesium, and zinc.
Halogens, halogen acids and possibly carbonyl halides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1018
- Shipping Name
- Chlorodifluoromethane or Refrigerant gas R 22
- Transport Class
- 2.2
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for R-22?
The signal word is warning.
What is the physical form of R-22?
R-22 is a gas at ambient temperatures appearing as clear, colorless liquid and vapor with colorless color. It has faint ethereal odor odor.
What is R-22 used for?
Refrigerant Gas
What are the hazard statements for R-22?
This substance has 1 hazard statement:
- H280: Contains gas under pressure, may explode if heated