Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SikaGrout®-316
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cement / Mortar
Manufacturers & Suppliers
Sika Deutschland GmbH
manufacturer
Kornwestheimer Str. 103-107, D-70439 Stuttgart
+49 711 8009 0
Emergency Contacts
Giftinformationszentrale Wien
0043 1 4064343
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Cement (chromium reduced) EC: 266-043-4 | 65997-15-1 | 25 - 40% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Consult a physician after significant exposure.
Symptoms: Cough, Respiratory disorder, May cause respiratory irritation.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician.
Symptoms: Erythema, Dermatitis, Causes skin irritation.
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Keep eye wide open while rinsing.
Symptoms: Small amounts splashed into eyes can cause irreversible tissue damage and blindness, Excessive lachrymation, Causes serious eye damage.
Do not induce vomiting without medical advice. Rinse mouth with water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Consult a physician after significant exposure. Seek medical advice.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Standard procedure for chemical fires.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Deny access to unprotected persons.
Try to prevent the material from entering drains or water courses.
Pick up and arrange disposal without creating dust.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid exceeding the given occupational exposure limits (see section 8). Do not get in eyes, on skin, or on clothing. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Follow standard hygiene measures when handling chemical products
Keep container tightly closed in a dry and well-ventilated place. Store in accordance with local regulations. Keep in a dry place.
Handle in accordance with good industrial hygiene and safety practice. When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Avoid dust formation.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation. This can be achieved by local exhaust extraction or by general ventilation. (EN 689 - Methods for determining inhalation exposure). This applies in particular to the mixing / stirring area.
Chemical-resistant, impervious gloves complying with an approved standard must be worn at all times when handling chemical products. Reference number EN 374. Follow manufacturer specifications. Recommended: Butyl rubber/nitrile rubber gloves.
Safety glasses with side-shields conforming to EN166. Eye wash bottle with pure water.
Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. particulate filter P. P1: Inert material; P2, P3: hazardous substances. In case this is not sufficient to keep the concentrations under the occupational exposure limits then respiration protection measures must be used.
Dust impervious protective suit. Protective clothing (e.g. Safety shoes acc. to EN ISO 20345, long-sleeved working clothing, long trousers). Rubber aprons and protective boots are additionally recommended for mixing and stirring work.
Try to prevent the material from entering drains or water courses.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable.
No dangerous reaction known under conditions of normal use.
Stable under recommended storage conditions.
No data available
No data available
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SikaGrout®-316?
The signal word is danger.
What is the physical form of SikaGrout®-316?
SikaGrout®-316 is a powder appearing as powder with grey color. It has odourless odor.
What is SikaGrout®-316 used for?
Cement / Mortar
What are the hazard statements for SikaGrout®-316?
This substance has 3 hazard statements:
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
What is the melting point of SikaGrout®-316?