NextSDS Logo
Safety Data Sheet EN

ALUMINIUM POWDER COATED 4.1 - stabilized

CAS 7429-90-5
EC 231-072-3

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ALUMINIUM POWDER COATED 4.1 - stabilized
Product Form
powder
Product Code
06 - 08 - 880 - 8880 - 8980 - 70000/2 - 024 - 030 - 032 - 76000 - 80000 - 80000/A - 90000/A - 30/Z - 40/Z - 80/Z - A8 - A88 - A888 - Silver Imitation*
Chemical Name
aluminium

Regulatory Identifiers

CAS Number
7429-90-5 Check regulations →
EC Number
231-072-3 Check regulations →
REACH No.
Submission number: MC178646-33 & Reference number: 05-2114281712-49-0000

Identified Uses

physically as a pigment

Manufacturers & Suppliers

AVL METAL POWDERS n.v. logo

AVL METAL POWDERS n.v.

manufacturer

Elleboogstraat 7, B-8500 KORTRIJK, West Flanders, Belgium, Europe

+32 (0)56 22 00 21

http://www.avlmetalpowders.com

Emergency Contacts

AVL METAL POWDERS n.v.

+32 (0)475 38 36 83

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Sol. Cat. 1 H228

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H228 Flammable solid.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. – No smoking.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P370 + P378 In case of fire use special powder for metal fires for extinction.
P370 + P378 In case of fire use dry sand for extinction.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
aluminium powder (stabilized) EC: 231-072-3 7429-90-5 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. Consult doctor in case of symptoms.

Skin contact

No special measures required.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.

Ingestion

In case of persistent symptoms consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use special powder for metal fires. Use dry sand.

Unsuitable media

Do not use water. Do not use foam. Do not use carbon dioxide. Do not use ABC powder.

Specific hazards

Contact with water liberates extremely flammable gas (hydrogen).

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away. Avoid causing dust. Keep away from ignition sources.

Environmental

Do not allow product to reach sewage system or water bodies.

Cleanup methods

Do not use a vacuum cleaner. Collect mechanically. Do not flush with water or aqueous cleansing agents.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent formation of dust. Any deposit of dust which cannot be avoided must be removed regularly.

Storage

Store in cool, dry place in tightly closed containers. Store only in the original container. Protect from humidity and keep away from water.

Fire prevention

Keep ignition sources away. - Do not smoke. Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Leather gloves. Long cuffed gloves.

Eyes

Face protection.

Respiratory

Use suitable breathing protection if workplace concentration requires. Filter P1.

Skin/Body

Anti-static safety shoes and fire resistant protective clothing (EN351; EN 533; EN 1149-1).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
---
Solidification Point
---
Physical State
Powder
Molecular Weight
---
Metal Corrosion
---
Flash Point
Not applicable.
State Under Standard Conditions
---
Odor Threshold
---
Colour Intensity
---
Vapor Density
---
Solubility
---
Solubility In Fat
---
Form
Powder
Upper Explosive Limit
---
Voc Content
---
Kinematic Viscosity
---
Odor
Odourless
Ph
---
Evaporation Rate
---
Vapor Pressure
---
Colour
Silver-coloured
Physical State Data
solid
Density
2.7 g/cm³
Flammability
Flammable. Contact with water liberates extremely flammable gases.
Properties Status
---
Bulk Density
0.15-0.35 g/cm³
Decomposition Temperature
---
Melting Point
660°C
Freezing Point
---
Boiling Point
> 999°C
Explosive Limits
---
Softening Point
---
Crystallisation Point
---
Relative Density
---
Appearance
Powder
Dynamic Viscosity
---
Auto Ignition Temperature
> 400°C
Solubility In Water
Insoluble
Relative Evaporation Rate
---
Cloud Point
---
Lower Explosive Limit
30 g/cm³
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition.

Reactivity

Contact with water may release flammable gasses. Reacts with alkalis, acids, halogenes and oxidizing agents. Reacts with halogenated compounds.

Hazardous reactions

Avoid dust clouds, they may form explosive dust-air-mixture.

Avoid

Avoid dust clouds

Incompatible

alkalis, acids, halogenes, oxidizing agents, halogenated compounds

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1309
Shipping Name
Aluminium powder, coated
Transport Class
4.1
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ALUMINIUM POWDER COATED 4.1 - stabilized?

The signal word is danger.

What is the physical form of ALUMINIUM POWDER COATED 4.1 - stabilized?

ALUMINIUM POWDER COATED 4.1 - stabilized is a powder appearing as powder with silver-coloured color. It has odourless odor.

What is ALUMINIUM POWDER COATED 4.1 - stabilized used for?

physically as a pigment

What are the hazard statements for ALUMINIUM POWDER COATED 4.1 - stabilized?

This substance has 1 hazard statement:

  • H228: Flammable solid.

What is the melting point of ALUMINIUM POWDER COATED 4.1 - stabilized?

The melting point is 660°C and the boiling point is > 999°C.