Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
ALUMINIUM RESISTANT CASTABLE is a mix of aggregate and fine powders substance .
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
THERMAL CERAMICS UK LTD
manufacturer
LIVERPOOL ROAD, NESTON, SOUTH WIRRAL CHESSHIRE, ENGLAND CH64 3RE
GB
44-(0)151-336-3911
44-(0)151-336-7868
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
These products have been specifically developed for molten aluminium applications
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Calcined Alumino-Silicates (40-46% Al_{2}O_{3}) | N/A | 77% | โ Non-hazardous |
| Calcined Bauxite | N/A | 85% | โ Non-hazardous |
| Aluminium Oxide Al_{2}O_{3} EC: 215-691-6 | 1344-28-1 | 3-8% | โ Non-hazardous |
| Fumed Silica EC: 273-761-1 | 69012-64-2 | 3-8% | โ Non-hazardous |
| Cement EC: 266-045-5 | 65997-15-1 | 2-7% | โ Non-hazardous |
| Barite BaSO_{4} EC: 236-664-5 | 136462-86-7 | 3-11% | โ Non-hazardous |
| Commissioning Additives | N/A | 1% | โ Non-hazardous |
Composition Notes
These products have been specifically developed for molten aluminium applications
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Remove to fresh air, drink water to clear throat and blow nose to evacuate dust.
Symptoms:
Irritation or soreness in throat and nose. In extreme exposures some congestion may occur.
๐๏ธ Skin Contact
Rinse affected areas with water and wash gently with soap.
Symptoms:
Temporary irritation or rash.
๐๏ธ Eye Contact
Flush eyes with large quantities of water.
Symptoms:
Temporary irritation or inflammation.
๐ฝ๏ธ Ingestion/Swallowing
Drink plenty of water.
Symptoms:
May cause temporary irritation and disturbance to the gastro-intestinal system.
๐จ Immediate Medical Attention Required
Seek medical attention if symptoms persist.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Use engineering control such as dust extraction a point of work to keep dust level to the lowest (See also Section 8 - Specific Control Parameters). In addition use a vacuum cleaner fitted with HEPA filters to collect debris.
๐งค Hand Protection
USE OF GLOVES IS RECOMMENDED.
๐๏ธ Eye Protection
Wear goggles or safety glasses with side shields. Do not wear contact lenses.
๐ท Respiratory Protection
Use approved and adapted protective equipments against excessive concentrations of nuisance dust, crystalline silica or other possible contaminants which could have been introduced in the material during its use. For airborne dust concentration below the limit value: optional use of approved and adapted respirator (e.g. 3M 5810 or equivalent). When the airborne dust concentration exceeds more than 3 times the limit value, use a mask such as 3M 9920 or Moldex Matrix 2405 or 3M Easy Air 7200 or equivalent. Insure always proper fit when using respiratory protection equipment.
๐ฆบ Skin/Body Protection
Wear overalls which are loose fitting at the neck and wrists.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for ALUMINIUM RESISTANT CASTABLE?
The signal word for this substance is "no signal word".
What is the physical form of ALUMINIUM RESISTANT CASTABLE?
ALUMINIUM RESISTANT CASTABLE is a mix of aggregate and fine powders appearing as mix of aggregate and fine powders with light grey color. It has no characteristic odour odor.
What is the melting point of ALUMINIUM RESISTANT CASTABLE?
The melting point is >1450C .