NextSDS Logo
Safety Data Sheet EN

DeriTool 667

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DeriTool 667
Product Code
ZL74500000000
Synonyms
VOC-frei

Regulatory Identifiers

CAS Number
N/A
REACH No.
01-2119475445-32-0000

Identified Uses

Thinner and cleaner for coating materials, described at the technical data sheets.

Manufacturers & Suppliers

D

Dr. Demuth Derisol Lackfarben GmbH & Co.KG

manufacturer

Hillerser Str. 8, D-37154 Northeim

+49 5551 97940

Emergency Contacts

Emergency Contact

+442071880100

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Wässrige Additivlösung

Full text of classification: see section 16

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest. In case of irregular breathing or respiratory arrest provide artificial respiration.

Skin contact

Take off immediately all contaminated clothing. After contact with skin, wash immediately with plenty of water and soap. Do not use solvents or thinners.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical advice immediately.

Ingestion

If swallowed, rinse mouth with water (only if the person is conscious). Seek medical advice immediately. Keep victim calm. Do NOT induce vomiting.

Immediate Medical Attention

Seek medical advice immediately.

Medical Treatment

First Aid, decontamination, treatment of symptoms.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

alcohol resistant foam, carbon dioxide, Powder, spray mist, (water)

Unsuitable media

strong water jet

Specific hazards

Dense black smoke occurs during fire. Inhaling hazardous decomposing products can cause serious health damage.

Instructions

Cool closed containers that are near the source of the fire.

Firefighter Protection

Provide a conveniently located respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep away from sources of ignition. Ventilate affected area. Do not breathe vapours.

Environmental

Do not allow to enter into surface water or drains.

Cleanup methods

Clean using cleansing agents. Do not use solvents.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid formation of flammable and explosive vapour concentrations in the air and exceeding the exposure limit values. Only use the material in places where open light, fire and other flammable sources can be kept away. Product may become electrostatically charged. Anti-static clothing including shoes are recommended. Floors must be electrically conductive. Avoid contact with skin, eyes and clothes. Do not inhale dusts, particulates and spray mist when using this preparation. Avoid respiration of swarf. When using do not eat, drink or smoke. Do not empty containers with pressure - no pressure vessel! Always keep in containers that correspond to the material of the original container.

Storage

Store in a well-ventilated and dry room at temperatures between 5 °C and 30 °C. Protect from heat and direct sunlight. Keep container tightly closed. Store carefully closed containers upright to prevent any leaks.

Hygiene

When using do not eat, drink or smoke.

Fire prevention

Keep away from heat sources, sparks and open flames. Use only spark proof tools. Electrical equipment must be protected meeting the accepted standard.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide good ventilation. This can be achieved with local or room suction.

Hands

For prolonged or repeated handling the following glove material must be used: NBR (Nitrile rubber) Thickness of the glove material > 0,4 mm; Breakthrough time: > 480 min. Observe the instructions and details for use, storage, maintenance and replacement provided by the protective glove manufacturer. Penetration time of glove material depending on intensity and duration of exposure to skin. Recommended glove articles EN ISO 374

Eyes

Wear closely fitting protective glasses in case of splashes.

Respiratory

If concentration of solvents is beyond the occupational exposure limit values, approved and suitable respiratory protection must be used. Use only respiratory protection equipment with CE-symbol including four digit test number.

Skin/Body

Wear antistatic clothing of natural fibers (cotton) or heat resistant synthetic fibers.

Environmental

Do not allow to enter into surface water or drains. See section 7. No additional measures necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
refer to label
Colour Intensity
---
Form
---
Odor
characteristic
Odor Threshold
not applicable
Ph
not applicable
Melting Point
-55 °C
Boiling Point
209 °C
Flash Point
> 100 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
not applicable
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,09 g/cm³
Flammability
Flammable solid.
Upper Explosive Limit
9 Vol-%
Lower Explosive Limit
0,8 Vol-%
Explosive Limits
---
Auto Ignition Temperature
not applicable
Decomposition Temperature
not applicable
Solubility
---
Partition Coefficient
see section 12
Solubility In Water
insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
20 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable when applying the recommended regulations for storage and handling. Further information on correct storage: refer to section 7.

Reactivity

No information available.

Hazardous reactions

Keep away from strong acids, strong bases and strong oxidizing agents to avoid exothermic reactions.

Avoid

Hazardous decomposition byproducts may form with exposure to high temperatures.

Incompatible

not applicable

Decomposition

Hazardous decomposition byproducts may form with exposure to high temperatures, e.g.: carbon dioxide, carbon monoxide, smoke, nitrogen oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8

IMDG

Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8

IATA

Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is DeriTool 667 known by?

DeriTool 667 is also known as: VOC-frei

What is the hazard signal word for DeriTool 667?

The signal word is no signal word.

What is the physical form of DeriTool 667?

DeriTool 667 is a liquid with refer to label color. It has characteristic odor.

What is DeriTool 667 used for?

Thinner and cleaner for coating materials, described at the technical data sheets.

What is the melting point of DeriTool 667?

The melting point is -55 °C and the boiling point is 209 °C.