NextSDS Logo
Safety Data Sheet EN

cis-1,3-Pentadiene

CAS 1574-41-0

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
cis-1,3-Pentadiene
Product Code
09207

Regulatory Identifiers

CAS Number
1574-41-0 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration or the annual tonnage does not require a registration.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

M

Merck Life Science BV/SRL

distributor

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS02 - Flammable

GHS02

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapour.
H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof electrical/ ventilating/ lighting equipment.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P331 Do NOT induce vomiting.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
(Z)-Penta-1,3-diene EC: 216-401-0 1574-41-0 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

caution if victim vomits. Risk of aspiration! Keep airways free. Pulmonary failure possible after aspiration of vomit. Call a physician immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides. Combustible. Pay attention to flashback. Vapours are heavier than air and may spread along floors. Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.

Instructions

Remove container from danger zone and cool with water.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.

Cleanup methods

Take up carefully with liquid-absorbent material (e.g. Chemizorb®).

Materials: liquid-absorbent material (e.g. Chemizorb®)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle and open container with care.

Storage

Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition. Store under argon.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type AX. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

required. Body Protection: Flame retardant antistatic protective clothing.

Environmental

Do not let product enter drains. Risk of explosion.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
light yellow
Colour
light yellow
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
---
Ph
---
Melting Point
-141 °C
Boiling Point
42 - 44 °C
Flash Point
-15 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
453,544 hPa at 20 °C; 1.485,39 hPa at 55 °C
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,692 g/cm³
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
1,5 % (V)
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Vapours may form explosive mixture with air.

Hazardous reactions

No data available

Avoid

Warming.

Incompatible

Oxidizing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3295
Shipping Name
HYDROCARBONS, LIQUID, N.O.S.
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for cis-1,3-Pentadiene?

The signal word is danger.

What is the physical form of cis-1,3-Pentadiene?

cis-1,3-Pentadiene is a liquid appearing as light yellow with light yellow color. It has no data available odor.

What is cis-1,3-Pentadiene used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for cis-1,3-Pentadiene?

This substance has 2 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H304: May be fatal if swallowed and enters airways.

What is the melting point of cis-1,3-Pentadiene?

The melting point is -141 °C and the boiling point is 42 - 44 °C.