NextSDS Logo
Safety Data Sheet EN

NOVA PTFE OIL AEROSOL

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NOVA PTFE OIL AEROSOL
Product Form
AEROSOL

Regulatory Identifiers

CAS Number
N/A
REACH No.
Not applicable (mixture)

Identified Uses

Lubricant

Uses advised against

No uses advised against known

Manufacturers & Suppliers

N

Novatio

distributor

Industrielaan 5B, B-2250 Olen

+32 14 25 76 40

N

Novatech International N.V.

manufacturer

Industrielaan 5B, B-2250 Olen

+32 14 85 97 37

Emergency Contacts

BIG

+32 14 58 45 45

24h/24h

EN, FR, DE, NL

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container: May burst if heated.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P273 Avoid release to the environment.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122°F.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 64742-55-8 25 - 50% Yes
propane EC: 200-827-9 74-98-6 12.5 - 20% Yes
hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 918-481-9 --- 10 - 12.5% Yes
butane EC: 203-448-7 106-97-8 10 - 12.5% Yes
pentane EC: 203-692-4 109-66-0 10 - 12.5% Yes
isobutane EC: 200-857-2 75-28-5 10 - 12.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim into fresh air. In case of respiratory problems, consult a doctor/medical service.

Symptoms: No effects known.

Skin contact

If possible, wipe up/dry remove chemical. Then rinse/shower immediately with (lukewarm) water. If irritation persists, consult a doctor/medical service.

Symptoms: ON CONTINUOUS/REPEATED EXPOSURE/CONTACT: Dry skin. Cracking of the skin.

Eye contact

Rinse immediately with (lukewarm) water. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation persists, consult a doctor/medical service.

Symptoms: No effects known.

Ingestion

Rinse mouth with water. If you feel unwell, consult a doctor/medical service. Do not wait for symptoms to occur to consult Poison Center.

Symptoms: No effects known.

Immediate Medical Attention

In case of injury and/or intoxication, call the European emergency number 112.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Small fire: Water, Quick-acting ABC powder extinguisher, Quick-acting BC powder extinguisher, Quick-acting CO2 extinguisher. Major fire: Quantities of water.

Specific hazards

Upon combustion: CO and CO2 are formed. Pressurised container: May burst if heated.

Instructions

If exposed to fire cool the closed containers by spraying with water. Physical explosion risk: extinguish/cool from behind cover. Do not move the load if exposed to heat. After cooling: persistent risk of physical explosion.

Firefighter Protection

Gloves (EN 374). Protective clothing (EN 14605 or EN 13034). Heat/fire exposure: self-contained breathing apparatus (EN 136 + EN 137).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop engines and no smoking. No naked flames or sparks. Spark- and explosionproof appliances and lighting equipment. Exposure to fire/heat: keep upwind. Exposure to fire/heat: have neighbourhood close doors and windows.

Environmental

Contain released product. Dam up the liquid spill.

Cleanup methods

Take up liquid spill into absorbent material. Scoop absorbed substance into closing containers. Carefully collect the spill/leftovers.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use spark-/explosionproof appliances and lighting system. Take precautions against electrostatic charges. Keep away from naked flames/heat. Keep away from ignition sources/sparks. Gas/vapour heavier than air at 20°C. Observe normal hygiene standards. Avoid prolonged and repeated contact with skin. Remove contaminated clothing immediately.

Storage

Storage temperature: < 50 °C. Meet the legal requirements. Keep container in a well-ventilated place. Fireproof storeroom. Keep out of direct sunlight.

Hygiene

Observe normal hygiene standards. Avoid prolonged and repeated contact with skin. Remove contaminated clothing immediately.

Fire prevention

Keep away from naked flames/heat. Keep away from ignition sources/sparks.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use spark-/explosionproof appliances and lighting system. Take precautions against electrostatic charges. Keep away from naked flames/heat. Keep away from ignition sources/sparks. Measure the concentration in the air regularly.

Hands

Hand protection not required in normal conditions.

Eyes

Protective goggles (EN 166).

Respiratory

Full face mask with filter type A at conc. in air > exposure limit.

Skin/Body

Protective clothing (EN 14605 or EN 13034). Head/neck protection.

Environmental

See sections 6.2, 6.3 and 13

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
Not applicable (aerosol)
Ph
Not applicable (non-soluble in water)
Upper Explosive Limit
10.9 vol %
Relative Density
0.70 ; 20 °C ; Liquid
Form
---
Auto Ignition Temperature
Not applicable (aerosol)
Crystallisation Point
---
Vapor Pressure
3500 hPa ; 20 °C ; Propellant
Bulk Density
---
Appearance
---
Voc Content
---
Decomposition Temperature
No data available in the literature
Partition Coefficient
Not applicable (mixture)
Relative Evaporation Rate
---
Molecular Weight
---
State Under Standard Conditions
---
Density
700 kg/m³ ; 20 °C ; Liquid
Evaporation Rate
---
Odor Threshold
No data available in the literature
Cloud Point
---
Explosive Limits
---
Properties Status
---
Physical State
Aerosol
Colour
Light brown
Physical State Data
aerosol
Softening Point
---
Vapor Density
---
Flammability
Extremely flammable aerosol.
Flash Point
Not applicable (aerosol)
Dynamic Viscosity
---
Solubility In Fat
---
Solidification Point
---
Boiling Point
No data available in the literature
Melting Point
Not applicable (aerosol)
Freezing Point
---
Odor
Solvent-like odour
Solubility In Water
insoluble
Lower Explosive Limit
0.6 vol %
Colour Intensity
---
Metal Corrosion
---
Solubility
Water ; insoluble
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

May be ignited by sparks. Gas/vapour spreads at floor level: ignition hazard.

Hazardous reactions

No data available.

Avoid

Use spark-/explosionproof appliances and lighting system. Take precautions against electrostatic charges. Keep away from naked flames/heat. Keep away from ignition sources/sparks.

Incompatible

No data available.

Decomposition

Upon combustion: CO and CO2 are formed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
aerosols
IMDG

190, 277, 327, 344, 381, 63, 959

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NOVA PTFE OIL AEROSOL?

The signal word is danger.

What is the physical form of NOVA PTFE OIL AEROSOL?

NOVA PTFE OIL AEROSOL is a aerosol with light brown color. It has solvent-like odour odor.

What is the solubility of NOVA PTFE OIL AEROSOL?

Water ; insoluble

What is NOVA PTFE OIL AEROSOL used for?

Lubricant

What are the hazard statements for NOVA PTFE OIL AEROSOL?

This substance has 3 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of NOVA PTFE OIL AEROSOL?

The melting point is Not applicable (aerosol) and the boiling point is No data available in the literature.