NextSDS Logo
Safety Data Sheet EN

Kryo 90

CAS 63148-62-9

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Kryo 90
Product Code
LZB 128, LZB 228, LZB 328

Regulatory Identifiers

CAS Number
63148-62-9 Check regulations →

Identified Uses

Heat transfer fluids, Industrial use, Professional uses / Public domain

Manufacturers & Suppliers

Lauda Dr. Wobser GmbH & Co. KG logo

Lauda Dr. Wobser GmbH & Co. KG

manufacturer

Pfarrstraße 41/43, 97922 Lauda-Königshofen, Germany

+49 (0)9343-503-0

http://www.lauda.de

Emergency Contacts

GIZ-Nord, Göttingen

+49 551-19240

CONSULTANK Lutz Harder GmbH (Contract QUALI003)

+49 (0)178-4337434

CONSULTANK Lutz Harder GmbH (Contract QUALI003)

01149 178 4337434

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H226 Flammable liquid and vapour.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P243 Take precautionary measures against static discharge.
P303 + P361 + P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container to hazardous or special waste collection point.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Polydimethylsiloxane 63148-62-9 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air. Seek medical treatment in case of troubles.

Skin contact

Remove residues with soap and water. In case of skin reactions, consult a physician.

Symptoms: Prolonged/repetitive skin contact may cause skin defattening or dermatitis.

Eye contact

Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Remove contact lenses, if present and easy to do. Continue rinsing. In case of eye irritation consult an ophthalmologist.

Symptoms: Can lead to eye ailments, however without permanent damage.

Ingestion

Do not induce vomiting. Immediately get medical attention.

Symptoms: When swallowed and vomited immediately, aspiration into the lungs may occur resulting in chemical pneumonia or suffocation.

Immediate Medical Attention

Immediately get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

water fog, alcohol resistant foam, extinguishing powder, carbon dioxide (CO2).

Unsuitable media

High power water jet

Specific hazards

Flammable liquid and vapour. With air, vapours form potentially explosive mixtures, which are heavier than air. May form dangerous gases and vapours in case of fire.

Instructions

Use fine water spray to cool endangered containers.

Firefighter Protection

Wear self-contained positive pressure breathing apparatus and full firefighting protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep unprotected people away. Do not breathe vapours. Provide fresh air. Avoid contact with skin and eyes. Remove all sources of ignition.

Environmental

Protect environment at risk.

Cleanup methods

Soak up with absorbent materials

Materials: sand, siliceus earth, acid- or universal binder

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapours. Avoid contact with skin and eyes.

Storage

Keep container tightly closed. Provide solvent resistant flooring.

Fire prevention

Smoking and welding strictly forbidden. Avoid open flames. Keep away from sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide good ventilation and/or an exhaust system in the work area.

Hands

Protective gloves according to EN 374. Glove material: Butyl caoutchouc (butyl rubber)-Layer thickness: 0,7 mm. Breakthrough time: >480 min. Observe glove manufacturer's instructions concerning penetrability and breakthrough time.

Eyes

Tightly sealed goggles according to EN 166

Respiratory

Respiratory protection in case of aerosol or vapour formation. Use filter type A (= against vapours of organic substances) according to EN 14387. (boiling temperature): >65 °C

Skin/Body

flame retardant protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Freezing Point
< -101 °C
Partition Coefficient
2.86 log P(o/w)
Ph
not applicable
Relative Density
---
Melting Point
no data available
Flammability
Flammable liquid and vapour.
Solubility In Fat
---
Appearance
clear
Cloud Point
---
Odor Threshold
no data available
Colour Intensity
---
Molecular Weight
---
Physical State
liquid
Upper Explosive Limit
12.50 Vol-%
Boiling Point
no data available
Vapor Pressure
<= 7 hPa (at 25 °C)
Solidification Point
---
Physical State Data
liquid
Kinematic Viscosity
1.66 mm²/s (at 20 °C)
Bulk Density
---
Decomposition Temperature
no data available
Lower Explosive Limit
0.70 Vol-%
Colour
clear
Flash Point
42 °C (c.c.)
Odor
odourless up to mild
Relative Evaporation Rate
---
Voc Content
---
Density
0.85 g/mL (at 25 °C)
Softening Point
---
Solubility
---
Evaporation Rate
<= 0.3 kg/s (estimated)
Crystallisation Point
---
Form
---
Vapor Density
no data available
Metal Corrosion
---
Auto Ignition Temperature
350 °C (ASTM D 2155)
Dynamic Viscosity
---
State Under Standard Conditions
---
Properties Status
---
Solubility In Water
insoluble <= 0.1 %
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Product is stable under normal storage conditions.

Reactivity

Flammable liquid and vapour. Vapours can form explosive mixtures with air.

Hazardous reactions

Do not expose to high temperature. Danger of bursting and explosion.

Avoid

Warmness

Incompatible

oxidizing agents, Acids, alkalis

Decomposition

May form dangerous gases and vapours in case of fire. In case of fire may be liberated: Formaldehyde, carbon monoxide and carbon dioxide. Thermal decomposition: no data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1993
Shipping Name
FLAMMABLE LIQUID, N.O.S. (Polydimethylsiloxane)
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Kryo 90?

The signal word is warning.

What is the physical form of Kryo 90?

Kryo 90 is a liquid appearing as clear with clear color. It has odourless up to mild odor.

What is Kryo 90 used for?

Heat transfer fluids, Industrial use, Professional uses / Public domain

What are the hazard statements for Kryo 90?

This substance has 1 hazard statement:

  • H226: Flammable liquid and vapour.

What is the melting point of Kryo 90?

The melting point is no data available and the boiling point is no data available.