Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CS-90
- Product Code
- UDS000841BU
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Professional use lubricants
Manufacturers & Suppliers
CRC Industries Europe UK Limited
manufacturer
Wylds Road, Castlefield Industrial Estate, TA6 4DD Bridgwater Somerset, United Kingdom
+44 1278 727200
http://www.crcind.com
CRC Industries Europe B.V.
Touwslagerstraat 1, 9240 Zele, Belgium
+32(0)52/45.60.11
http://www.crcind.com
Emergency Contacts
Emergency Contact
+44 1278 727200
9-17h CET
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Talc (Mg3H2(SiO3)4) EC: 238-877-9 | 14807-96-6 | 10 - 30% | No |
| graphite EC: 231-955-3 | 7782-42-5 | 5 - 10% | No |
| Copper flakes (coated with aliphatic acid) | --- | 5 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing.
Symptoms: None under normal conditions.
Wash skin with plenty of water.
Rinse eyes with water as a precaution.
Call a poison center or a doctor if you feel unwell.
Immediate Medical Attention
If signs/symptoms develop, get medical attention (inhalation). Seek medical attention if irritation develops (skin/eye).
Medical Treatment
Provide general supportive measures and treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray. Dry powder. Foam. Carbon dioxide.
Do not use a heavy water stream.
Move containers from fire area if it can be done without personal risk. Use standard firefighting procedures and consider the hazards of other involved materials.
Firefighter Protection
Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ventilate spillage area. Evacuate unnecessary personnel.
Take up small spills with dry chemical absorbent.
confine the spill in a dike and charge it with wet sand or earth for subsequent safe disposal. Following product recovery, flush area with water.
Avoid release to the environment.
Clean surface thoroughly to remove residual contamination.
Materials: dry chemical absorbent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment. Ensure good ventilation of the work station. Avoid prolonged exposure. Handle in accordance with good industrial hygiene and safety procedures.
Store in a well-ventilated place. Keep cool. Keep container closed when not in use.
Do not eat, drink or smoke when using this product. Always wash hands after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.
Wear suitable gloves tested to EN374. The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile gloves are recommended.
Use eye protection according to EN 166. Safety glasses with side shields.
No respiratory protection needed under normal use conditions. In case of insufficient ventilation, wear suitable respiratory equipment
Wear suitable protective clothing
Avoid release to the environment. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
The product is non-reactive under normal conditions of use, storage and transport.
No dangerous reactions known under normal conditions of use.
None under recommended storage and handling conditions (see section 7). Avoid temperatures exceeding the flash point.
Strong oxidizing agents.
Under normal conditions of storage and use, hazardous decomposition products should not be produced. Carbon oxides (CO, CO2).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3077
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Copper, diphenylamine)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CS-90?
The signal word is warning.
What is the physical form of CS-90?
CS-90 is a liquid appearing as paste. with brown. color. It has characteristic. odor.
What is the solubility of CS-90?
Immiscible with water.
What is CS-90 used for?
Professional use lubricants
What are the hazard statements for CS-90?
This substance has 1 hazard statement:
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of CS-90?
The melting point is No data available and the boiling point is Not available.