Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CS-90
Product Code
UDS000841BU

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional use lubricants

Manufacturers & Suppliers

CRC Industries Europe UK Limited logo

CRC Industries Europe UK Limited

manufacturer

Wylds Road, Castlefield Industrial Estate, TA6 4DD Bridgwater Somerset, United Kingdom

+44 1278 727200

http://www.crcind.com

CRC Industries Europe B.V. logo

CRC Industries Europe B.V.

Touwslagerstraat 1, 9240 Zele, Belgium

+32(0)52/45.60.11

http://www.crcind.com

Emergency Contacts

Emergency Contact

+44 1278 727200

9-17h CET

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Aquatic Acute Cat. 1 H400
Aquatic Chronic Cat. 1 H410

GHS Pictograms

GHS09 - Environmental hazard

GHS09

Hazard Statements

H410 Very toxic to aquatic life with long lasting effects.

Precautionary Statements

P102 Keep out of reach of children.
P273 Avoid release to the environment.
P391 Collect spillage.
P501 Dispose of contents/container to a hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Talc (Mg3H2(SiO3)4) EC: 238-877-9 14807-96-6 10 - 30% No
graphite EC: 231-955-3 7782-42-5 5 - 10% No
Copper flakes (coated with aliphatic acid) --- 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing.

Symptoms: None under normal conditions.

Skin contact

Wash skin with plenty of water.

Eye contact

Rinse eyes with water as a precaution.

Ingestion

Call a poison center or a doctor if you feel unwell.

Immediate Medical Attention

If signs/symptoms develop, get medical attention (inhalation). Seek medical attention if irritation develops (skin/eye).

Medical Treatment

Provide general supportive measures and treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Dry powder. Foam. Carbon dioxide.

Unsuitable media

Do not use a heavy water stream.

Instructions

Move containers from fire area if it can be done without personal risk. Use standard firefighting procedures and consider the hazards of other involved materials.

Firefighter Protection

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ventilate spillage area. Evacuate unnecessary personnel.

Small spill

Take up small spills with dry chemical absorbent.

Large spill

confine the spill in a dike and charge it with wet sand or earth for subsequent safe disposal. Following product recovery, flush area with water.

Environmental

Avoid release to the environment.

Cleanup methods

Clean surface thoroughly to remove residual contamination.

Materials: dry chemical absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment. Ensure good ventilation of the work station. Avoid prolonged exposure. Handle in accordance with good industrial hygiene and safety procedures.

Storage

Store in a well-ventilated place. Keep cool. Keep container closed when not in use.

Hygiene

Do not eat, drink or smoke when using this product. Always wash hands after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Wear suitable gloves tested to EN374. The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile gloves are recommended.

Eyes

Use eye protection according to EN 166. Safety glasses with side shields.

Respiratory

No respiratory protection needed under normal use conditions. In case of insufficient ventilation, wear suitable respiratory equipment

Skin/Body

Wear suitable protective clothing

Environmental

Avoid release to the environment. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Paste.
Colour
Brown.
Colour Intensity
---
Form
---
Odor
Characteristic.
Odor Threshold
Not available
Ph
Not applicable
Melting Point
No data available
Boiling Point
Not available
Flash Point
Not available
Freezing Point
Not available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not available
Vapor Density
---
Relative Density
Not available
Bulk Density
---
Density
Not available
Flammability
Non flammable.
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
---
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Immiscible with water.
Partition Coefficient
Not applicable
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

No dangerous reactions known under normal conditions of use.

Avoid

None under recommended storage and handling conditions (see section 7). Avoid temperatures exceeding the flash point.

Incompatible

Strong oxidizing agents.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced. Carbon oxides (CO, CO2).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3077
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (Copper, diphenylamine)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CS-90?

The signal word is warning.

What is the physical form of CS-90?

CS-90 is a liquid appearing as paste. with brown. color. It has characteristic. odor.

What is the solubility of CS-90?

Immiscible with water.

What is CS-90 used for?

Professional use lubricants

What are the hazard statements for CS-90?

This substance has 1 hazard statement:

  • H410: Very toxic to aquatic life with long lasting effects.

What is the melting point of CS-90?

The melting point is No data available and the boiling point is Not available.