Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Norcamphor
- Product Code
- 129250000; 129250050; 129250250; 129251000
- Chemical Name
- Norcamphor
- Synonyms
- 2-Norbornanone; Bicyclo[2.2.1]heptan-2-one
Regulatory Identifiers
- CAS Number
- 497-38-1 Check regulations →
- EC Number
- 207-846-1 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
national supplier
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Acros Organics BVBA
national supplier
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Fisher Scientific
001-800-ACROS-01
Fisher Scientific
+32 14 57 52 11
Fisher Scientific
001-201-796-7100
Fisher Scientific
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Bicyclo[2.2.1]heptan-2-one EC: 207-846-1 | 497-38-1 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from exposure, lie down. Remove to fresh air.
Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. Get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water. Get medical attention.
Immediate Medical Attention
Get medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray. Carbon dioxide (CO₂). Dry chemical. Chemical foam.
No information available.
Flammable. Combustible material.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
See Section 12 for additional Ecological Information.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Do not breathe dust. Use spark-proof tools and explosion-proof equipment. Use only non-sparking tools.
Keep in a dry place. Keep container tightly closed. Keep away from heat, sparks and flame. Flammables area.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Keep away from heat, sparks and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use explosion-proof electrical/ventilating/lighting/equipment. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Nitrile rubber, Neoprene, Natural rubber, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Wear appropriate protective gloves and clothing to prevent skin exposure. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
Hazardous polymerization does not occur. No information available.
Keep away from open flames, hot surfaces and sources of ignition. Incompatible products.
Strong oxidizing agents.
Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1325
- Shipping Name
- Flammable solid, organic, n.o.s
- Transport Class
- 4.1
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Norcamphor known by?
Norcamphor is also known as: 2-Norbornanone; Bicyclo[2.2.1]heptan-2-one
What is the hazard signal word for Norcamphor?
The signal word is warning.
What is the physical form of Norcamphor?
Norcamphor is a solid appearing as white . It has odorless odor.
What is Norcamphor used for?
Laboratory chemicals.
What are the hazard statements for Norcamphor?
This substance has 1 hazard statement:
- H228: Flammable solid
What is the melting point of Norcamphor?
The melting point is 88 - 91 °C / 190.4 - 195.8 °F and the boiling point is 168 - 172 °C / 334.4 - 341.6 °F @ 760 mmHg.