Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Compressor Oil 1 L
- Product Code
- 0901004170
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricant for Industrial use, Compressor lubricant
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Metabowerke GmbH
manufacturer
Metabo-Allee-1 – DE-72622 Nürtingen
0049 / (0) 7022 / 72-0
Emergency Contacts
NHS
+44 (0) 344 892 0111
NHS
111
NHS 24
111
Emergency Contact
01 809 2166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Product based on mineral oil with a DMSO extract <3% (IP 346).
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Destillate (Erdöl), mit Wasserstoff behandelte schwere, naphthenhaltige | --- | --- | No |
For the wording of the listed hazard phrases refer to section 16.
Notes
Dangerous components: Void
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Rinse out mouth and then drink plenty of water. No neutralization attempt. Do not induce vomiting.
Symptoms: Gastric or intestinal disorders
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
In case of fire, the following can be released: oxides of carbon, Nitrogen oxides (NOx), Smoke
Cool endangered containers with water spray from a safe distance. Do not inhale explosion and combustion gases.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Particular danger of slipping on leaked/spilled product.
Do not allow to penetrate the ground/soil. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material
Related Products
Similar products with comparable safety profiles
PAG 46, R-134a lubricant, 240 mL
---
CompAir Fluid Force 2000hr Universal Screw Lubricant
---
Air Tool Lubricant
---
MOTIP CUT & DRILL LUBRICANT 500 ML
---
Cat Pump Crankcase Oil ISO 68
CAS: Mixture
Industrial oil - Hantlom "LOH" lubricant oil
---
TUNAIR 100 20I D-GB-F-I-E-PL Kompres.öl
---
Used Lubricating Oil (for laboratory testing purposes)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The usual precautionary measures when handling chemicals should be observed.
Store in a cool location. Store in cool, dry conditions in well sealed receptacles. Protect from frost.
Vapors are heavier than air. Explosive vapor - / air - mixtures may be formed avoid rake at high temperatures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Recommendation: Chemical resistant protective gloves (EN 374). Material of gloves: Nitrile rubber, NBR; Chloroprene rubber, CR. Recommended thickness of the material: ≥ 0.4 mm. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: Value for the permeation: Level 6 = >480 min. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. Supplementary note: The specifications are based on own tests, literature data and information of glove manufacturers, or is derived by analogy with similar substances. It should be noted, that the practical usage of a chemical-protective glove can in practice due to many influencing factors (eg temperature) may be considerably shorter than the permeation time determined through testing. Due to the large variety the instructions of the manufacturer must be observed.
Use safety glasses according to EN 166 : 2001.
Not necessary if room is well-ventilated. Exceeding the recommended exposure limits: In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Respiratory protective device with combination filter (EN143 / EN 149): Typ P2 / FFP2. Respirators and components must be tested and approved under appropriate government standards such as NIOSH. (U.S.) or CEN (EU).
Impervious protective clothing. Non-slip shoes recommended
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under normal ambient conditions (room temperature).
Reacts with strong oxidants and strong reducing agents under severe heat.
No dangerous reactions known.
Temperatures above 60 °C can lead to reduced shelf life of the product.
No further relevant information available.
Emergence of flammable gases / vapors on contact with strong oxidizing agent's possible.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Compressor Oil 1 L?
The signal word is no signal word.
What is the physical form of Compressor Oil 1 L?
Compressor Oil 1 L is a fluid appearing as fluid with yellowish color. It has characteristic odor.
What is Compressor Oil 1 L used for?
Lubricant for Industrial use, Compressor lubricant
What is the melting point of Compressor Oil 1 L?
The melting point is Undetermined. and the boiling point is Undetermined..