Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PFINDER AP 759
Product Code
07590000

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Cleaning agent/ Cleaner

Manufacturers & Suppliers

P

Pfinder KG

manufacturer

Rudolf-Diesel-Str. 14, D-71032 Böblingen

+49 (0)7031 2701-0

Emergency Contacts

Vergiftungs-Informations-Zentrale Universitätsklinikum Freiburg

+49 (0)761 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P260 Do not breathe mist/vapours/spray.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor/...
P331 Do NOT induce vomiting.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/ national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Solvent mixture

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C12-C16, isoalkanes, cyclics, <2% aromatics EC: 927-676-8 --- 25 - 50% Yes
Distillates (petroleum), hydrotreated middle EC: 934-956-3 64742-46-7 25 - 50% Yes
Hydrocarbons, C13-C16, n-alkanes, isoalkanes, cyclics, <0,03% aromatics EC: 934-954-2 64742-46-7 25 - 50% Yes

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist. In case of unconsciousness place patient stably in side position for transportation. In case of inhalation of aerosols remove the casualty into fresh air and seek medical advice.

Skin contact

Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Do not induce vomiting; call for medical help immediately.

Symptoms: If swallowed or in the event of vomiting may cause aspiration into the lungs which can be fatal.

Immediate Medical Attention

call for medical help immediately

Medical Treatment

If swallowed or in the event of vomiting may cause aspiration into the lungs which can be fatal.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, dry powder, carbon dioxide, water spray jet

Unsuitable media

Water with full jet

Specific hazards

Fire gas of organic material has to be classed invariably as respiratory poison. Vapours are heavier than air and spread on ground. Product possibly swims up on surface and reinflames.

Instructions

Cool endangered receptacles with water spray.

Firefighter Protection

Wear self-contained respiratory protective device. Wear fully protective suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow to enter sewers/ surface or ground water. Do not allow to penetrate the ground/soil.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols. Use solvent-proof equipment. Use only in well ventilated areas. Ensure good interior ventilation, especially at floor level. (Fumes are heavier than air). Tightly reclose container after each use. Keep away from sources of ignition - No smoking. Avoid contact with eyes and skin.

Storage

Store in a cool location. Store in cool, dry conditions in well sealed receptacles. Store receptacle in a well ventilated area.

Hygiene

Avoid contact with eyes and skin.

Fire prevention

Keep ignition sources away - Do not smoke. Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Solvent resistant gloves. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Recommended thickness of the material: >= 0,7 mm. Permeation time >= 480 minutes. Nitrile rubber, NBR. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

Use suitable respiratory protective device in case of insufficient ventilation. Breathing apparatus in the event of aerosol or mist formation. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Gas filter type A (organic gases and vapours).

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
---
Partition Coefficient
---
Cloud Point
---
Odor
Mild
Auto Ignition Temperature
---
Kinematic Viscosity
at 40,00 °C 2,55 mm2/s
Properties Status
---
Relative Density
---
Lower Explosive Limit
0,60 Vol %
Physical State
Liquid
Vapor Density
---
Colour
Colourless
Solidification Point
---
Flash Point
ca. 101 °C
Colour Intensity
---
Relative Evaporation Rate
---
Bulk Density
---
Physical State Data
liquid
Flammability
Not applicable.
Metal Corrosion
---
Solubility In Water
Insoluble.
Density
15°C: ca. 0,806 g/ml
Vapor Pressure
at 20,00 °C 0,0900 hPa
Boiling Point
234,0 °C
Molecular Weight
---
Crystallisation Point
---
Dynamic Viscosity
Not determined.
Freezing Point
---
Softening Point
---
Melting Point
---
Evaporation Rate
---
Decomposition Temperature
---
Ph
Not determined.
Voc Content
---
State Under Standard Conditions
---
Solubility
---
Upper Explosive Limit
7,00 Vol %
Form
Liquid
Explosive Limits
---
Solubility In Fat
---
Odor Threshold
Not determined.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

No dangerous reactions known.

Avoid

Flames, sparks, heat.

Incompatible

Strong oxidizing agents

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PFINDER AP 759?

The signal word is danger.

What is the physical form of PFINDER AP 759?

PFINDER AP 759 is a liquid with colourless color. It has mild odor.

What is PFINDER AP 759 used for?

SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Cleaning agent/ Cleaner

What are the hazard statements for PFINDER AP 759?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.