Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PFINDER UBS 693/7
- Product Code
- 06930700
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Underbody wax; The product is intended for professional use.
Manufacturers & Suppliers
Pfinder KG
manufacturer
Rudolf-Diesel-Str. 14, D-71032 Boeblingen
+49 (0)7031 2701-0
Emergency Contacts
Emergency Contact
+27 21 300 2732
Carechem 24 International-NCEC
+44 1235 239671
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Alkyd resins, anticorrosion additives (sulphonates), mineral oil, pigments, thickener, additives
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbon waxes (petroleum), oxidized EC: 265-205-1 | 64743-00-6 | --- | Yes |
| Rapeseed oil, reaction products with diethylenetriamine EC: 293-615-0 | 91081-13-9 | 1 - 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Seek immediate medical advice.
Symptoms: If swallowed or in the event of vomiting may cause aspiration into the lungs which can be fatal.
Immediate Medical Attention
Seek immediate medical advice.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, dry powder, carbon dioxide, water mist
Water with full jet
Fire gas of organic material has to be classed invariably as respiratory poison.
Firefighter Protection
Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water. Do not allow to penetrate the ground/soil.
Absorb with liquid-binding material
Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Avoid the formation of oil haze. Tightly reclose container after each use. Avoid contact with eyes and skin. In case of formation of aerosols an adequate exhaustion is necessary.
Store in cool, dry conditions in well sealed receptacles. Store under inert gas.
Evolution of flammable mixtures possible in air when heated above flash point and/or during spraying or misting. The product is an oxidative drying system. With such systems contaminated cleaning rags tends to spontaneous inflammation! Used cleaning material must be stored in nonflammable containers with shut tightly cover.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. In case of skin contact wear suitable gloves. Material of gloves: Nitrile rubber, NBR. Recommended thickness of the material: >= 0,7 mm. Permeation time >= 480 minutes. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses
Use suitable respiratory protective device in case of insufficient ventilation. Combined filter: Particle-filtering half mask (filter P2 or P3) and gas filter (type A, colour brown). Respiratory protection in the event of aerosol or mist formation
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No dangerous reactions known.
Very high temperatures and direct exposure to sunlight. Do not leave containers open.
Strong oxidizing agents
Danger of forming toxic pyrolysis products.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PFINDER UBS 693/7?
The signal word is no signal word.
What is PFINDER UBS 693/7 used for?
Underbody wax; The product is intended for professional use.