Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Prime Ultra LS Putty
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Knife filler/ Surfacer
Manufacturers & Suppliers
MIPA SE
manufacturer
Am Oberen Moos 1, D-84051 Essenbach
+49(0)8703-922-0
http://www.mipa-paints.com
KCC Corporation
distributor
344, Sapyeong-daero, Seocho-gu, Seoul
Emergency Contacts
KCC Corporation
+82-2-3480-5000
MIPA SE
+49(0)700 24112112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Styrene EC: 202-851-5 | 100-42-5 | 5 - 10% | Yes |
| vinyltoluene EC: 246-562-2 | 25013-15-4 | 2.5 - 10% | Yes |
| 2,2'-(m-tolylimino)diethanol EC: 202-114-8 | 91-99-6 | 0.1 - 1% | Yes |
| Reaction mass of 2,2'-[(4-methylphenyl)imino] bisethanol and Ethanol 2-[2-(2-hydroxyethoxy)ethyl][4-methylphenyl)amino]- EC: 911-490-9 | --- | 0.1 - 1% | Yes |
| maleic anhydride EC: 203-571-6 | 108-31-6 | 0.001 - 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air and to be sure call for a doctor. In case of unconsciousness place patient stably in side position for transportation.
Immediately rinse with water.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
During heating or in case of fire poisonous gases are produced.
Firefighter Protection
Mouth respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Open and handle receptacle with care. Keep respiratory protective device available.
Keep container tightly sealed.
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves (EN 374). The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
Carbon monoxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3269
- Shipping Name
- POLYESTER RESIN KIT
- Transport Class
- 3
- Packing Group
- III
Warning: Flammable liquids.
Warning: Flammable liquids.
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Prime Ultra LS Putty?
The signal word is warning.
What is the physical form of Prime Ultra LS Putty?
Prime Ultra LS Putty is a fluid with according to product specification color. It has characteristic odor.
What is the solubility of Prime Ultra LS Putty?
Not miscible or difficult to mix.
What is Prime Ultra LS Putty used for?
Knife filler/ Surfacer
What are the hazard statements for Prime Ultra LS Putty?
This substance has 6 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H361d: Suspected of damaging the unborn child.
- H373: May cause damage to the hearing organs through prolonged or repeated exposure.
What is the melting point of Prime Ultra LS Putty?
The melting point is Undetermined. and the boiling point is 145.2 °C.