Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Putty Hardener
- Product Code
- 0200
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Not available.
Uses advised against
None known.
Manufacturers & Suppliers
ITW Performance Polymers
manufacturer
Bay 150, Shannon Industrial Estate, Co. Clare, Ireland, V14 DF82
353(61)771500
Emergency Contacts
Emergency Contact
44(0) 1235 239 670
24 hours
General in EU
112
Available 24 hours a day.
Austria National Poisons Information Center
+431 406 4343
Available 24 hours a day.
Belgium National Poisons Control Center
070 245 245
Available 24 hours a day.
Bulgaria National Toxicological Information Center
+359 2 9154 233
Available 24 hours a day.
Croatia Poisons Information Center
+385 1 2348 342
Cyprus Poison Center
1401
Available 24 hours a day.
Czech Republic National Poisons Information Center
+420 224 919 293
Czech Republic National Poisons Information Center
+420 224 915 402
Denmark National Poisons Control Center
+45 82 12 12 12
Available 24 hours a day.
Estonia National Poisons Information Center
16662
Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays).
Estonia National Poisons Information Center
(+372) 626 9390
Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays).
Finland National Poison Information Center
(09) 471 977
Available 24 hours a day.
Finland National Poison Information Center
(09) 4711
Available 24 hours a day.
France National Poisons Control Center
+33 (0) 1 45 42 59 59
Available 24 hours a day.
Greece Poison Information Centre
(0030) 2107793777
Available 24 hours a day.
Hungary National Emergency Phone Number
+36-80-201-199
Available 24 hours a day.
Iceland Poison Center
(+354) 543 2222
Available 24 hours a day.
Latvia Emergency medical aid
113
Latvia Poison and Drug Information Center
+371 67042473
Available 24 hours a day.
Lithuania Neatidéliotina informacija apsinuodijus
+370 5 236 20 52
Lithuania Neatidéliotina informacija apsinuodijus
+37068753378
Malta Accident and Emergency Department
2545 4030
Netherlands National Poisons Information Center (NVIC)
+31 (0)88 755 8000
Norway Norwegian Poison Information Center
22 59 13 00
Available 24 hours a day.
Portugal Poison Center
800 250 250
Available 24 hours a day.
Romania Biroul RSI si Informare Toxicologica
021.318.36.06
Available 8:00AM-3:00PM.
Slovakia National Toxicological Information Center
+421 2 5477 4166
Available 24 hours a day.
Spain Toxicology Information Service
+34 91 562 04 20
Available 24 hours a day.
Sweden National Poison Information Center
112
Available 24 hours a day.
Switzerland Tox Info Suisse
145
Available 24 hours a day.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Fatty Acids, C18-unsatd., Dimers, Oligomeric Reaction Products With Tall-oil Fatty Acids And Triethylenetetramine EC: 500-191-5 | 68082-29-1 | 50 - 60% | Yes |
| 3,6-diazaoctanethylenediamin; triethylenetetramine EC: 203-950-6 | 112-24-3 | 20 - 30% | Yes |
| PHENOL, STYRENATED EC: 262-975-0 | 61788-44-1 | 5 - 10% | Yes |
| 1-(2-aminoethyl)piperazine EC: 205-411-0 | 140-31-8 | 3 - 5% | Yes |
| titanium dioxide [in powder form containing 1 % or more of particles with aerodynamic diameter ≤ 10 μm] EC: 236-675-5 | 13463-67-7 | 1 - 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Call a physician if symptoms develop or persist.
Remove contaminated clothing immediately and wash skin with soap and water. Call a physician or poison control center immediately. Chemical burns must be treated by a physician. Wash contaminated clothing before reuse.
Symptoms: Burning pain and severe corrosive skin damage.
Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Call a physician or poison control center immediately.
Symptoms: Causes serious eye damage. Symptoms may include stinging, tearing, redness, swelling, and blurred vision. Permanent eye damage including blindness could result.
Call a physician or poison control center immediately. Rinse mouth. Do not induce vomiting. If vomiting occurs, keep head low so that stomach content doesn't get into the lungs.
Immediate Medical Attention
Call a physician or poison control center immediately.
Medical Treatment
Chemical burns must be treated by a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol resistant foam. Powder. Carbon dioxide (CO2).
Do not use water jet as an extinguisher, as this will spread the fire.
No unusual fire or explosion hazards noted.
Move containers from fire area if you can do so without risk. Use standard firefighting procedures and consider the hazards of other involved materials.
Firefighter Protection
Self-contained breathing apparatus and full protective clothing must be worn in case of fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe mist/vapors. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep unnecessary personnel away.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.
Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all environmental releases. Prevent further leakage or spillage if safe to do so.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Materials: absorbent material (e.g. cloth, fleece)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe mist/vapors. Do not get in eyes, on skin, or on clothing. Avoid prolonged exposure. When using, do not eat, drink or smoke. Pregnant or breastfeeding women must not handle this product. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Wash contaminated clothing before reuse.
Store locked up. Store in tightly closed container.
When using, do not eat, drink or smoke. Wash hands thoroughly after handling. Wash contaminated clothing before reuse. Observe good industrial hygiene practices.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Eye wash facilities and emergency shower must be available when handling this product.
Wear appropriate chemical resistant gloves.
Wear safety glasses with side shields (or goggles).
In case of insufficient ventilation, wear suitable respiratory equipment.
Wear appropriate chemical resistant clothing. Use of an impervious apron is recommended.
Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Contact with incompatible materials.
Peroxides. Phenols.
No hazardous decomposition products are known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2735
- Shipping Name
- AMINES, LIQUID, CORROSIVE, N.O.S. (3,6-diazaoctanethylenediamin; triethylenetetramine)
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Putty Hardener?
The signal word is danger.
What is the physical form of Putty Hardener?
Putty Hardener is a liquid. with cream color. It has amine odor.
What is Putty Hardener used for?
Not available.
What are the hazard statements for Putty Hardener?
This substance has 7 hazard statements:
- H312: Harmful in contact with skin.
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H361: Suspected of damaging fertility or the unborn child.
- H373: May cause damage to organs through prolonged or repeated exposure.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Putty Hardener?
The melting point is 53,6 °F (12 °C) estimated and the boiling point is 510,8 °F (266 °C) estimated.