Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- tesa 60020 60021 Spray Glue PERMANENT
- Product Code
- tesa 60020 (300ml) + 60021 (500ml)
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesives
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
tesa SE
manufacturer
Hugo-Kirchberg-Strasse 1, D-22848 Norderstedt, Germany
+49-40-88899-101
Emergency Contacts
tesa SE
+49-40-88899-0
tesa SE
+49-40-88899-9111
The UK National Poisons Emergency
0870 600 6266
Guy's & St Thomas' Poisons Unit
+44 (0)20 7188 0100
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Dispersion of natural rubber and resins in the following substances:
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Naphtha (petroleum), hydrotreated light EC: 265-151-9 | 64742-49-0 | 50% | Yes |
| cyclohexane EC: 203-806-2 | 110-82-7 | 25% | Yes |
| propane liquefied EC: 200-827-9 | 74-98-6 | 25% | Yes |
| isobutane EC: 200-857-2 | 75-28-5 | 25% | Yes |
| butane, pure EC: 203-448-7 | 106-97-8 | 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness bring patient into stable side position for transport.
Instantly wash with water and soap and rinse thoroughly.
Rinse opened eyes for several minutes under running water.
In case of persistent symptoms consult physician.
Medical Treatment
If swallowed, gastric irrigation with added, activated carbon.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, extinguishing powder or water jet. Fight larger fires with water jet or alcohol-resistant foam.
Can be released in case of fire: Nitrogen oxide (NOx) Carbon monoxide (CO)
Firefighter Protection
Put on breathing apparatus. Do not inhale explosion gases or combustion gases.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Prevent product from reaching sewage system or water bodies.
Related Products
Similar products with comparable safety profiles
tesa 60020 60021 Spray Glue PERMANENT
---
tesa Spray Glue extra strong / Spray Glue Mounting
---
tesa Adhesive Remover Spray
---
DGT® SolventGlue EC.00
---
Loctite Spray Adhesive Multi Purpose
---
DGT® SolventGlue EC.7
---
ULINE S-15802 HEAVY DUTY SPRAY ADHESIVE
CAS: Not Applicable (mixture)
DGT SolventGlue® HYBRID LS-ST
UFI: 8G20-N02D-Y009-UWCG
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and direct sunlight. Ensure good ventilation/exhaustion at the workplace.
Observe official regulations on storing packagings with pressurised containers. Keep container tightly sealed.
Do not spray on flames or red-hot objects. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: use solvent stable gloves. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Not required.
Breathing equipment: Use breathing filter A2. In case of short term exposure use respiratory protection. In case of intensive or longer exposure use respiratory protection equipment independent from ambient air.
Protective work clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Void
Warning: Gases.
Warning: Gases. SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow 'separated from' class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for tesa 60020 60021 Spray Glue PERMANENT?
The signal word is danger.
What is the physical form of tesa 60020 60021 Spray Glue PERMANENT?
tesa 60020 60021 Spray Glue PERMANENT is a aerosol appearing as light yellow with light yellow color. It has solvent-like odor.
What is tesa 60020 60021 Spray Glue PERMANENT used for?
Adhesives
What are the hazard statements for tesa 60020 60021 Spray Glue PERMANENT?
This substance has 4 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of tesa 60020 60021 Spray Glue PERMANENT?
The melting point is Not determined and the boiling point is -44 °C.