Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PERGUT S 10
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Binder for coating materials or adhesives
Manufacturers & Suppliers
Covestro Deutschland AG
manufacturer
Covestro-IO-S&A-PSRA-PSI, 51365 Leverkusen
+49 214 6009 4068
Emergency Contacts
Sicherheitszentrale Bayer
+49 214 30 99300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Chlorinated Polymer
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Chlorinated Polymer | --- | 100% | No |
| toluene EC: 203-625-9 | 108-88-3 | 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If high concentrations of the dusts have been inhaled, the person should be taken into the fresh air and kept still and warm. If there is difficulty in breathing, medical attention should be obtained.
In case of skin contact wash affected areas thoroughly with soap and plenty of water. Consult a doctor in the event of a skin reaction.
Hold the eyes open and rinse with preferably lukewarm water for a sufficiently long period of time (at least 10 minutes). Contact an ophthalmologist.
DO NOT induce the patient to vomit, medical advice is required.
Immediate Medical Attention
If there is difficulty in breathing, medical attention should be obtained. Consult a doctor in the event of a skin reaction. Contact an ophthalmologist. Medical advice is required if swallowed.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2), Foam, extinguishing powder, in cases of larger fires, water spray should be used.
High volume water jet
Formation of hydrogen chloride in case of fire. In the event of fire and/or explosion do not breathe fumes.
Fight fire in early stages if safe to do so. Cool undamaged containers with water.
Firefighter Protection
During fire-fighting respirator with independent air-supply and airtight garment is required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Put on protective equipment (see section 8). Ensure adequate ventilation/exhaust extraction. Keep unauthorized persons away.
Do not allow to escape into waterways, wastewater or soil.
Use mechanical handling equipment.
Materials: Fill into labeled, sealable containers.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Vapors of toluene may be released on heating or placing in solution and can accumulate during storage in closed container. Handle in accordance with good industrial hygiene and safety practice.
Keep container dry and tightly closed in a cool and well ventilated place.
Handle in accordance with good industrial hygiene and safety practice. Keep away from foodstuffs, drinks and tobacco. Wash hands before breaks and at the end of workday. Keep working clothes separately. Change contaminated clothing.
Take measures to prevent the build up of electrostatic charge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Suitable materials for safety gloves; EN 374: Nitrile rubber - NBR: thickness >=0,35mm; breakthrough time >=480min. Recommendation: contaminated gloves should be disposed of.
Wear eye/face protection.
If product forms dust wear dust-protection mask. Respiratory equipment required during spraying of the coating.
Wear suitable protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Decomposition begins at 255 °C.
This information is not available.
This information is not available.
This information is not available.
This information is not available.
No hazardous decomposition products when stored and handled correctly.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
See section 6 - 8. Keep dry. Keep separated from foodstuffs.
See section 6 - 8. Keep dry. Keep separated from foodstuffs.
See section 6 - 8. Keep dry. Keep separated from foodstuffs.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PERGUT S 10?
The signal word is no signal word.
What is the physical form of PERGUT S 10?
PERGUT S 10 is a solid appearing as powder with white color. It has almost odourless odor.
What is PERGUT S 10 used for?
Binder for coating materials or adhesives
What is the melting point of PERGUT S 10?
The melting point is 200 - 250 °C DIN 53736 and the boiling point is not applicable.