Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ECO-PHYL® PLASTORIT[®] 0.5, PLASTORIT[®] 0.25
- Chemical Name
- Leucophyllite
Regulatory Identifiers
- CAS Number
- 999999-99-4 Check regulations →
- EC Number
- 310-127-6 Check regulations →
- REACH No.
- Exempted in accordance with Annex V.7.
Identified Uses
Functional mineral for use in industrial applications.
Manufacturers & Suppliers
Imerys Talc Austria GmbH
manufacturer
Andritzer Reichsstraβe 26 8045 Graz Austria
+43 316 69 36 50
Emergency Contacts
Company
+1 303 623 5716
Available outside office hours: Yes
National centre for Prevention and Treatment of Intoxications
see annex 2
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Chlorite EC: 215-285-9 | 1318-59-8 | 30 - 50% | No |
| Mica | 12001-26-2 | 20 - 30% | No |
| Quartz EC: 238-878-4 | 14808-60-7 | 30 - 50% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Movement of the exposed individual from the area to fresh air is recommended.
Symptoms: Cough and breathlessness (symptoms of silicosis).
No special first aid measures necessary.
Rinse with copious quantities of water and seek medical attention if irritation persists.
No first aid measures required.
Immediate Medical Attention
No specific actions are required
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
No specific extinguishing media is needed.
No restriction on the extinguishing media to be used.
Non-combustible.
Firefighter Protection
No specific fire-fighting protection is required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special requirements.
use water spraying or vacuum cleaning systems (with high-efficiency particulate air filter)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid airborne dust generation. Handle packaged products carefully to prevent accidental bursting.
Keep containers closed and store packaged products so as to prevent accidental bursting.
Do not eat, drink or smoke when using this product. Wash hands thoroughly after handling. Remove contaminated clothing and protective equipment before entering eating areas. Shower and change clothes at end of work shift.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Minimise airborne dust generation. Use process enclosures, local exhaust ventilation or other engineering controls to keep airborne levels below specified exposure limits. If user operations generate dust, fumes or mist, use ventilation to keep exposure to airborne particles below the exposure limit. Apply organisational measures, e.g. by isolating personnel from dusty areas.
Appropriate protection (e.g. gloves, barrier cream) is recommended for workers who suffer from dermatitis or sensitive skin.
Wear safety glasses with side-shields in circumstances where there is a risk of penetrative eye injuries.
The use of half or full face masks with filters against particles of category 2 or 3 (FP2 - FP3) is recommended. See EN 143: 2000 - Respiratory protective devices. Particle filters.
No specific requirement.
Avoid wind dispersal
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Chemically stable.
Inert, not reactive
No hazardous reaction.
Not relevant
No particular incompatibility.
Not relevant
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ECO-PHYL® PLASTORIT[®] 0.5, PLASTORIT[®] 0.25?
The signal word is no signal word.
What is the physical form of ECO-PHYL® PLASTORIT[®] 0.5, PLASTORIT[®] 0.25?
ECO-PHYL® PLASTORIT[®] 0.5, PLASTORIT[®] 0.25 is a solid appearing as solid with greyish/white color.
What is ECO-PHYL® PLASTORIT[®] 0.5, PLASTORIT[®] 0.25 used for?
Functional mineral for use in industrial applications.
What is the melting point of ECO-PHYL® PLASTORIT[®] 0.5, PLASTORIT[®] 0.25?
The melting point is >1300°C and the boiling point is not applicable (inorganic solid with a melting point > 1300°C).