Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BAYHYDUR BL XP 2706
- Product Code
- 112000023727
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hardener for coating materials for industrial or trade applications
Manufacturers & Suppliers
Covestro Pty Ltd.
manufacturer
Level 1, 700 Springvale Road MULGRAVE, VIC 3170 AUSTRALIA
(61) 3-9581-9888
Rebain International (Aust) Pty
distributor
53-55 Rodeo Drive Dandenong South, Vic, 3175
+61 3 9706 9400
Emergency Contacts
IXOM SH&E Shared Services
1800 033 111
IXOM SH&E Shared Services
0800 734 607
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 3,5-dimethylpyrazole EC: 200-657-5 | 67-51-6 | 1.1% | Yes |
| Acetone EC: 200-662-2 | 67-64-1 | 1% | Yes |
| 5-chloro-2-methyl-3(2H)-isothiazolone / 2-methyl-3(2H)-isothiazolone (3:1) | 55965-84-9 | 0.0015% | Yes |
| 2-dimethylaminoethanol EC: 203-542-8 | 108-01-0 | 2.8% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Take the person into the fresh air and keep him warm, let him rest.
Wash off immediately with soap and plenty of water.
Hold the eyes open and rinse with preferably lukewarm water for a sufficiently long period of time (at least 10 minutes).
If accidentally swallowed obtain immediate medical attention.
Immediate Medical Attention
In case of irritation of the respiratory tract seek medical advice. Consult a doctor in the event of a skin reaction. Contact an ophthalmologist. If accidentally swallowed obtain immediate medical attention.
Medical Treatment
No information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2), Foam, extinguishing powder, in cases of larger fires, water spray should be used.
High volume water jet
Burning releases carbon monoxide, carbon dioxide, oxides of nitrogen and traces of hydrogen cyanide. In the event of fire and/or explosion do not breathe fumes.
Firefighter Protection
In the event of fire and/or explosion do not breathe fumes.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Put on protective equipment (see section 8). Ensure adequate ventilation/exhaust extraction. Keep unauthorized persons away.
Do not allow to escape into waterways, wastewater or soil.
Take up with absorbent for chemicals or, if necessary with dry sand and store in closed containers.
Materials: absorbent for chemicals, dry sand
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
When handling observe the usual precautionary measures for chemicals. Avoid contact with skin and eyes.
Keep container dry and tightly closed in a cool and well ventilated place.
Keep away from foodstuffs, drinks and tobacco. Wash hands before breaks and at the end of workday. Keep working clothes separately. Change contaminated or soaked clothing.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Suitable materials for safety gloves; EN 374: Nitrile rubber - NBR: thickness >=0,35mm; breakthrough time >=480min. Butyl rubber - IIR: thickness >=0,5mm; breakthrough time >=480min. Fluorinated rubber - FKM: thickness >=0,4mm; breakthrough time >=480min. Recommendation: contaminated gloves should be disposed of.
Wear eye/face protection.
Respiratory protection required in insufficiently ventilated working areas and during spraying.
Wear suitable protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Under stoving conditions dimethyl pyrazol is split off. Stoving gases should be extracted.
This information is not available.
No hazardous reactions when used as directed.
This information is not available.
This information is not available.
On drying of the coating / hardening release of neutralising agent. (see section 3)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
See section 6 - 8. Avoid heat above +40 °C. Avoid temperatures below +5 °C. Keep separated from foodstuffs.
See section 6 - 8. Avoid heat above +40 °C. Avoid temperatures below +5 °C. Keep separated from foodstuffs.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BAYHYDUR BL XP 2706?
The signal word is no signal word.
What is the physical form of BAYHYDUR BL XP 2706?
BAYHYDUR BL XP 2706 is a liquid appearing as liquid with yellowish color. It has slight inherent odour odor.
What is BAYHYDUR BL XP 2706 used for?
Hardener for coating materials for industrial or trade applications