Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ACTIRON DNNS
- Product Code
- M6-12913
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Catalyst.
Manufacturers & Suppliers
SYNTHRON
manufacturer
6, rue Barbès F-92305 LEVALLOIS-PERRET
(33)-01-41-34-14-00
Emergency Contacts
ORFILA (authorised advisory centre)
(33)-01-45-42-59-59
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Alkylarylsulfonic acid in a glycolether solution.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Alkylarylsulfonic acid EC: 246-841-9 | 25322-17-2 | 50 - 60% | Yes |
| Ethylene glycol monobutyl ether EC: 203-905-0 | 111-76-2 | 40 - 50% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Make victim breath fresh air. In case of respiratory failure artificial respiration.
Symptoms: Respiratory tract irritation
Wash immediately with water.
Symptoms: inflammation
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist.
Symptoms: Eye Irritation, Corneal injury
Make the victim rinse his mouth with water. Do not make the victim vomit.
Symptoms: Nausea
Immediate Medical Attention
When in doubt or if symptoms are observed, get medical advice. In case of accident or unwellness, seek medical advice immediately. If an inflammation appears alert a physican. Consult an ophthalmologist.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Sprayed water. Powder. Foam. Carbonic snow.
Jet of water from a fire hose.
Use water spray jet to protect personnel and to cool endangered containers.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: Personal protection equipment: see section 8. For emergency responders: Personal protection equipment: see
Cover drains. Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it. Ensure waste is collected and contained.
Absorb with liquid-binding material ( e.g. sand, diatomaceous earth or universal binding agents). Collect in closed and suitable containers for disposal. Wash with plenty of water.
Materials: liquid-binding material ( e.g. sand, diatomaceous earth or universal binding agents)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid: Skin contact. Eye contact. Use only in well-ventilated areas.
Recommended storage temperature: At room temperature
Not to eat, drink and smoke in work areas. To wash hands after use. To remove contaminated clothing and protective equipment before entering eating areas.
Avoid accumulating electrostatic charge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
See chapter 7. No additional measures necessary.
Chemical resistant protective gloves (DIN EN 374). The product Suitable material: Butyl caoutchouc (butyl rubber) By long-term hand contact - Breakthrough time (maximum wear duration): > 8 h - Thickness of the glove material: 0.7 mm - Protection class /EN 374: 6
Goggles/Face protection shield (DIN 166).
Respiratory protection necessary at: Exposure limit overshoot. Insufficient ventilation. Handling larger quantities. Manifestation of side effects: respiratory irritation, nausea, discomfort. Full/half-face mask (DIN EN 136/DIN EN 140) with filter type (DIN EN 14387): A.
Wearing of fully sealed work clothing is recommended. Suitable protective clothing: Chemical protection clothing. Chemical resistant safety shoes.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No hazardous reactions if stored and handled as prescribed/indicated.
No hazardous reactions if stored and handled as prescribed/indicated.
Decompostion takes place from temperatures above: 150 °C
Strong oxidising agents.
No hazardous decomposition products if stored and handled as prescribed/indicated.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ACTIRON DNNS?
The signal word is na: r-phrases.
What is the physical form of ACTIRON DNNS?
ACTIRON DNNS is a liquid appearing as liquid. color: dark brown. with dark brown color. It has of solvents odor.
What is ACTIRON DNNS used for?
Catalyst.
What is the melting point of ACTIRON DNNS?
The melting point is No data available and the boiling point is >150 °C.