Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CRILAT 7829
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Water dispersion of synthetic polymers.
Manufacturers & Suppliers
VINAVIL S.p.A.
manufacturer
Via Valtellina, 63 - 20159 MILAN - ITALY
+(39)02-695541
Emergency Contacts
VINAVIL S.p.A.- Villadossola Plant
+(39)0324-5031
office hours
Poison Centre - Ospedale di Niguarda - Milan
+39/02/66101029
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,2-benzisotiazol-3(2H)-one EC: 220-120-9 | 2634-33-5 | 0.005 - 0.01% | Yes |
| reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2-methyl-2H -isothiazol-3-one [EC no. 220-239-6] (3:1) | 55965-84-9 | 0.00015 - 0.0015% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest.
Wash with plenty of water and soap.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Wash immediately with water for at least 10 minutes.
A suspension of activated charcoal in water, or petrolium jelly may be administered. Wash the mouth thoroughly and drink plenty of water.
Immediate Medical Attention
In case of disease consult a physician immediately and present this safety-data sheet.
Medical Treatment
Treatment: (see paragraph 4.1)
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
None in particular.
None in particular.
The product does not present a fire hazard. Do not inhale explosion and combustion gases.
Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear personal protection equipment. Remove persons to safety. See protective measures under point 7 and 8.
Limit leakages with earth or sand. Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes, inhalation of vapours and mists. See also section 8 for recommended protective equipment. Do not remove shrink film in hazardous locations (because of risk of static charging/discharge)
Store above 5°C.
Do not eat or drink while working. Keep away from food, drink and feed.
Keep away from open flames, heat and sparks.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Not needed for normal use.
Not needed for normal use.
Not needed for normal use. In case of insufficient ventilation use mask with B type filters (EN 14387).
No special precaution must be adopted for normal use.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions
Stable under normal conditions
Stable under normal conditions.
None in particular.
None.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CRILAT 7829?
The signal word is no signal word.
What is the physical form of CRILAT 7829?
CRILAT 7829 is a liquid appearing as liquid with white color. It has typical odor.
What is CRILAT 7829 used for?
Water dispersion of synthetic polymers.
What is the melting point of CRILAT 7829?
The melting point is N.A. and the boiling point is 100 °C.