NextSDS Logo
Safety Data Sheet EN

CRILAT 7829

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CRILAT 7829

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Water dispersion of synthetic polymers.

Manufacturers & Suppliers

V

VINAVIL S.p.A.

manufacturer

Via Valtellina, 63 - 20159 MILAN - ITALY

+(39)02-695541

Emergency Contacts

VINAVIL S.p.A.- Villadossola Plant

+(39)0324-5031

office hours

Poison Centre - Ospedale di Niguarda - Milan

+39/02/66101029

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
1,2-benzisotiazol-3(2H)-one EC: 220-120-9 2634-33-5 0.005 - 0.01% Yes
reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2-methyl-2H -isothiazol-3-one [EC no. 220-239-6] (3:1) 55965-84-9 0.00015 - 0.0015% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest.

Skin contact

Wash with plenty of water and soap.

Eye contact

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Wash immediately with water for at least 10 minutes.

Ingestion

A suspension of activated charcoal in water, or petrolium jelly may be administered. Wash the mouth thoroughly and drink plenty of water.

Immediate Medical Attention

In case of disease consult a physician immediately and present this safety-data sheet.

Medical Treatment

Treatment: (see paragraph 4.1)

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

None in particular.

Unsuitable media

None in particular.

Specific hazards

The product does not present a fire hazard. Do not inhale explosion and combustion gases.

Instructions

Move undamaged containers from immediate hazard area if it can be done safely.

Firefighter Protection

Use suitable breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear personal protection equipment. Remove persons to safety. See protective measures under point 7 and 8.

Environmental

Limit leakages with earth or sand. Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes, inhalation of vapours and mists. See also section 8 for recommended protective equipment. Do not remove shrink film in hazardous locations (because of risk of static charging/discharge)

Storage

Store above 5°C.

Hygiene

Do not eat or drink while working. Keep away from food, drink and feed.

Fire prevention

Keep away from open flames, heat and sparks.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Not needed for normal use.

Eyes

Not needed for normal use.

Respiratory

Not needed for normal use. In case of insufficient ventilation use mask with B type filters (EN 14387).

Skin/Body

No special precaution must be adopted for normal use.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State Data
liquid
Cloud Point
---
Metal Corrosion
---
Flash Point
N.A.
Evaporation Rate
---
Freezing Point
---
Bulk Density
---
State Under Standard Conditions
---
Flammability
---
Physical State
liquid
Molecular Weight
---
Kinematic Viscosity
N.A.
Softening Point
---
Ph
8,0
Relative Evaporation Rate
---
Melting Point
N.A.
Solubility In Fat
insoluble
Crystallisation Point
---
Relative Density
1,06 g/cm³ (23°C)
Properties Status
---
Lower Explosive Limit
N.A.
Solidification Point
---
Explosive Limits
---
Odor Threshold
N.A.
Colour Intensity
---
Decomposition Temperature
N.A.
Form
---
Partition Coefficient
N.A.
Density
---
Solubility
---
Upper Explosive Limit
N.A.
Appearance
liquid
Dynamic Viscosity
N.A.
Odor
typical
Solubility In Water
dispersible
Vapor Pressure
---
Boiling Point
100 °C
Voc Content
---
Colour
white
Auto Ignition Temperature
N.A.
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions

Reactivity

Stable under normal conditions

Avoid

Stable under normal conditions.

Incompatible

None in particular.

Decomposition

None.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CRILAT 7829?

The signal word is no signal word.

What is the physical form of CRILAT 7829?

CRILAT 7829 is a liquid appearing as liquid with white color. It has typical odor.

What is CRILAT 7829 used for?

Water dispersion of synthetic polymers.

What is the melting point of CRILAT 7829?

The melting point is N.A. and the boiling point is 100 °C.