01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HSV 1 & 2 PCR Mix
Product Form
Mixture
Product Code
RTK403ING-M

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial/Professional use spec : For professional use only Use of the substance/mixture : In vitro diagnostic medical device component

Uses advised against

No additional information available

Manufacturers & Suppliers

E

ELITechGroup Inc. Molecular Diagnostics, Inc

manufacturer

21720 23rd Dr SE Suite 150, Bothell, WA 98021 - USA

1-800-453-2725

Emergency Contacts

InfoTrac Emergency Response

1-800-535-5053

InfoTrac Emergency Response

+1-352-323-3500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH annex II

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing.

Skin contact

Wash skin with plenty of water.

Eye contact

Rinse eyes with water as a precaution.

Ingestion

Call a poison center/doctor/physician if you feel unwell.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Dry powder. Foam. Carbon dioxide.

Firefighter Protection

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ventilate spillage area.

Environmental

Avoid release to the environment.

Cleanup methods

Take up liquid spill into absorbent material.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation of the work station. Wear personal protective equipment.

Storage

Store in a well-ventilated place. Keep cool.

Hygiene

Do not eat, drink or smoke when using this product. Always wash hands after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation of the work station.

Hands

Protective gloves

Eyes

Safety glasses

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment

Skin/Body

Wear suitable protective clothing

Environmental

Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
No data available
Auto Ignition Temperature
No data available
Boiling Point
> 100°C at 100.000 Pa
Physical State
Liquid
Bulk Density
---
Ph
9.0
Solubility In Fat
---
Melting Point
Not applicable
Appearance
---
Physical State Data
liquid
Flash Point
No data available
Relative Density
1.000 Kg/L
Solubility
Fully miscible in water
Lower Explosive Limit
No data available
Dynamic Viscosity
No data available
Partition Coefficient
No data available
Explosive Limits
---
Crystallisation Point
---
Solubility In Water
---
Cloud Point
---
Density
---
Colour Intensity
---
Solidification Point
---
Relative Evaporation Rate
No data available
Metal Corrosion
---
Flammability
Not applicable
State Under Standard Conditions
---
Molecular Weight
---
Vapor Pressure
No data available
Colour
Light pink
Vapor Density
---
Upper Explosive Limit
No data available
Decomposition Temperature
No data available
Softening Point
---
Voc Content
---
Form
---
Odor
characteristic.
Properties Status
---
Freezing Point
No data available
Evaporation Rate
---
Kinematic Viscosity
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

No dangerous reactions known under normal conditions of use.

Avoid

None under recommended storage and handling conditions (see section 7).

Incompatible

No additional information available

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HSV 1 & 2 PCR Mix?

The signal word is no signal word.

What is the physical form of HSV 1 & 2 PCR Mix?

HSV 1 & 2 PCR Mix is a liquid with light pink color. It has characteristic. odor.

What is the solubility of HSV 1 & 2 PCR Mix?

Fully miscible in water

What is HSV 1 & 2 PCR Mix used for?

Industrial/Professional use spec : For professional use only Use of the substance/mixture : In vitro diagnostic medical device component

What is the melting point of HSV 1 & 2 PCR Mix?

The melting point is Not applicable and the boiling point is > 100°C at 100.000 Pa.