Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RENOIR RED DILUENT (PD904)
Product Form
Mixture
Product Code
PD904

Regulatory Identifiers

CAS Number
N/A

Identified Uses

No use is specified.

Manufacturers & Suppliers

Biocare Medical logo

Biocare Medical

manufacturer

60 Berry Drive, Pacheco, CA, 94553

1-800-799-9499

http://www.biocare.net

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

1-03-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Met. Corr. Cat. 1 H290
Eye Dam. Cat. 1 H318
Aquatic Acute Cat. 3 H402

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H290 May be corrosive to metals.
H318 Causes serious eye damage.
H402 Harmful to aquatic life.

Precautionary Statements

P234 Keep only in original container.
P273 Avoid release to the environment.
P280 Wear protective gloves, protective clothing, and eye protection.
P305 + P351 + P338 If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a poison center or doctor.
P390 Absorb spillage to prevent material-damage.
P406 Store in corrosive resistant container with a resistant inner liner.
P501 Dispose of contents/container in accordance with local, regional, national, and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Proprietary Ingredient A --- 9.56% Yes
Proprietary Ingredient B --- 0.085395 - 0.08989% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

When symptoms occur: go into open air and ventilate suspected area. Obtain medical attention if breathing difficulty persists.

Symptoms: Prolonged exposure may cause irritation.

Skin contact

Immediately drench affected area with water for at least 15 minutes. Remove contaminated clothing. Obtain medical attention if irritation develops or persists.

Symptoms: Prolonged exposure may cause skin irritation.

Eye contact

Immediately rinse with water for at least 30 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get immediate medical advice/attention.

Symptoms: Causes permanent damage to the cornea, iris, or conjunctiva.

Ingestion

Rinse mouth. Do NOT induce vomiting. Obtain medical attention.

Symptoms: Ingestion may cause adverse effects.

Immediate Medical Attention

Get immediate medical advice/attention (for eye contact).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, fog, carbon dioxide (CO₂), alcohol-resistant foam, or dry chemical.

Unsuitable media

Do not use a heavy water stream. Use of heavy stream of water may spread fire.

Specific hazards

Not considered flammable but may burn at high temperatures. Contact with metallic substances may release flammable hydrogen gas. May be corrosive to metals.

Instructions

Use water spray or fog for cooling exposed containers.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Upon arrival at the scene, a first responder is expected to recognize the presence of dangerous goods, protect oneself and the public, secure the area, and call for the assistance of trained personnel as soon as conditions permit. Ventilate area.

Environmental

Avoid release to the environment.

Cleanup methods

Clean up spills immediately and dispose of waste safely. Transfer spilled material to a suitable container for disposal. Absorb spillage to prevent material damage.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Avoid breathing vapors, mist, spray. Do not get in eyes, on skin, or on clothing.

Storage

Keep container closed when not in use. Store in a dry, cool place. Keep/Store away from direct sunlight, extremely high or low temperatures and incompatible materials. Store in corrosive resistant container with a resistant inner liner.

Hygiene

Handle in accordance with good industrial hygiene and safety procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Ensure all national/local regulations are observed. Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure.

Hands

Wear protective gloves.

Eyes

Chemical safety goggles.

Respiratory

If exposure limits are exceeded or irritation is experienced, approved respiratory protection should be worn. In case of inadequate ventilation, oxygen deficient atmosphere, or where exposure levels are not known wear approved respiratory protection.

Skin/Body

Wear suitable protective clothing. Chemically resistant materials and fabrics.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
No data available
Colour
---
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
No data available
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended handling and storage conditions (see Section 7).

Reactivity

May be corrosive to metals. Contact with metals may evolve flammable hydrogen gas.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Direct sunlight, extremely high or low temperatures, and incompatible materials.

Incompatible

incompatible materials

Decomposition

None expected under normal conditions of use.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1789
Shipping Name
HYDROCHLORIC ACID SOLUTION
Transport Class
8
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RENOIR RED DILUENT (PD904)?

The signal word is danger.

What is the physical form of RENOIR RED DILUENT (PD904)?

RENOIR RED DILUENT (PD904) is a liquid appearing as no data available . It has no data available odor.

What is the solubility of RENOIR RED DILUENT (PD904)?

No data available

What is RENOIR RED DILUENT (PD904) used for?

No use is specified.

What are the hazard statements for RENOIR RED DILUENT (PD904)?

This substance has 3 hazard statements:

  • H290: May be corrosive to metals.
  • H318: Causes serious eye damage.
  • H402: Harmful to aquatic life.

What is the melting point of RENOIR RED DILUENT (PD904)?