Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RENOIR RED DILUENT (PD904)
- Product Form
- Mixture
- Product Code
- PD904
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
No use is specified.
Manufacturers & Suppliers
Biocare Medical
manufacturer
60 Berry Drive, Pacheco, CA, 94553
1-800-799-9499
http://www.biocare.net
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
1-03-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Proprietary Ingredient A | --- | 9.56% | Yes |
| Proprietary Ingredient B | --- | 0.085395 - 0.08989% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
When symptoms occur: go into open air and ventilate suspected area. Obtain medical attention if breathing difficulty persists.
Symptoms: Prolonged exposure may cause irritation.
Immediately drench affected area with water for at least 15 minutes. Remove contaminated clothing. Obtain medical attention if irritation develops or persists.
Symptoms: Prolonged exposure may cause skin irritation.
Immediately rinse with water for at least 30 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get immediate medical advice/attention.
Symptoms: Causes permanent damage to the cornea, iris, or conjunctiva.
Rinse mouth. Do NOT induce vomiting. Obtain medical attention.
Symptoms: Ingestion may cause adverse effects.
Immediate Medical Attention
Get immediate medical advice/attention (for eye contact).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, fog, carbon dioxide (CO₂), alcohol-resistant foam, or dry chemical.
Do not use a heavy water stream. Use of heavy stream of water may spread fire.
Not considered flammable but may burn at high temperatures. Contact with metallic substances may release flammable hydrogen gas. May be corrosive to metals.
Use water spray or fog for cooling exposed containers.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Upon arrival at the scene, a first responder is expected to recognize the presence of dangerous goods, protect oneself and the public, secure the area, and call for the assistance of trained personnel as soon as conditions permit. Ventilate area.
Avoid release to the environment.
Clean up spills immediately and dispose of waste safely. Transfer spilled material to a suitable container for disposal. Absorb spillage to prevent material damage.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Avoid breathing vapors, mist, spray. Do not get in eyes, on skin, or on clothing.
Keep container closed when not in use. Store in a dry, cool place. Keep/Store away from direct sunlight, extremely high or low temperatures and incompatible materials. Store in corrosive resistant container with a resistant inner liner.
Handle in accordance with good industrial hygiene and safety procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure all national/local regulations are observed. Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure.
Wear protective gloves.
Chemical safety goggles.
If exposure limits are exceeded or irritation is experienced, approved respiratory protection should be worn. In case of inadequate ventilation, oxygen deficient atmosphere, or where exposure levels are not known wear approved respiratory protection.
Wear suitable protective clothing. Chemically resistant materials and fabrics.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended handling and storage conditions (see Section 7).
May be corrosive to metals. Contact with metals may evolve flammable hydrogen gas.
Hazardous polymerization will not occur.
Direct sunlight, extremely high or low temperatures, and incompatible materials.
incompatible materials
None expected under normal conditions of use.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1789
- Shipping Name
- HYDROCHLORIC ACID SOLUTION
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RENOIR RED DILUENT (PD904)?
The signal word is danger.
What is the physical form of RENOIR RED DILUENT (PD904)?
RENOIR RED DILUENT (PD904) is a liquid appearing as no data available . It has no data available odor.
What is the solubility of RENOIR RED DILUENT (PD904)?
No data available
What is RENOIR RED DILUENT (PD904) used for?
No use is specified.
What are the hazard statements for RENOIR RED DILUENT (PD904)?
This substance has 3 hazard statements:
- H290: May be corrosive to metals.
- H318: Causes serious eye damage.
- H402: Harmful to aquatic life.
What is the melting point of RENOIR RED DILUENT (PD904)?
The melting point is No data available and the boiling point is No data available.