Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Acetonitrile
- Product Code
- 0120
- Chemical Name
- Cyanomethane
Regulatory Identifiers
- CAS Number
- 75-05-8 Check regulations →
- EC Number
- 200-835-2 Check regulations →
- REACH No.
- 01-2119471307-38-XXXX
Identified Uses
Chemical for research, development, manufacturing, laboratory chemical for analysis.
Manufacturers & Suppliers
Biosolve Chimie
manufacturer
20 Rue Roger Husson, 57260 Dieuze, France
+33 3 878 675 80/81/82/83/84/85
Biosolve B.V.
manufacturer
Kerkhofstraat 21, 5554HG Valkenswaard, the Netherlands.
+31-(0)40-2071300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetonitrile EC: 200-835-2 | 75-05-8 | --- | No |
12.12.2014
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist. In case of unconsciousness place patient stably in side position for transportation.
Generally the product does not irritate the skin.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Call for a doctor immediately.
Immediate Medical Attention
Call for a doctor immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Firefighter Protection
Mouth respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas. Keep unprotected persons away.
Dilute with plenty of water.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Store in a cool location. Keep container tightly sealed. Store in cool, dry conditions in well sealed receptacles.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Butyl rubber, BR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: Full contact: Material: butyl-rubber, Minimum layer thickness: 0.3 mm, Break through time: 480 min. Splash contact: Material: butyl-rubber, Minimum layer thickness: 0.3 mm, Break through time: 480 min. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly sealed goggles
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
Protective work clothing
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1648
- Shipping Name
- ACETONITRILE
- Transport Class
- 3
- Packing Group
- II
Warning: Flammable liquids.
Warning: Flammable liquids.
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Acetonitrile?
The signal word is danger.
What is the physical form of Acetonitrile?
Acetonitrile is a liquid with colourless color. It has ether-like odor.
What is Acetonitrile used for?
Chemical for research, development, manufacturing, laboratory chemical for analysis.
What are the hazard statements for Acetonitrile?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.
- H319: Causes serious eye irritation.
What is the melting point of Acetonitrile?