Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
5-(Hydroxymethyl)furfural
Product Code
W501808
Chemical Name
5-(Hydroxymethyl)furfural

Regulatory Identifiers

CAS Number
67-47-0 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

M

Merck Life Science BV/SRL

manufacturer

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P280 Wear protective gloves/ eye protection/ face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P332 + P313 If skin irritation occurs: Get medical advice/ attention.
P337 + P313 If eye irritation persists: Get medical advice/ attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
5-(Hydroxymethyl)-2-furaldehyde EC: 200-654-9 67-47-0 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most).

Immediate Medical Attention

Call in ophthalmologist. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO2) Foam Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating.

Instructions

Remove container from danger zone and cool with water.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge. Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

Storage

Tightly closed. Dry.

Hygiene

Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact: Material: butyl-rubber, Minimum layer thickness: 0,3 mm, Break through time: 480 min, Material tested: Butoject® (KCL 897 / Aldrich Z677647, Size M). Splash contact: Material: butyl-rubber, Minimum layer thickness: 0,3 mm, Break through time: 480 min, Material tested: Butoject® (KCL 897 / Aldrich Z677647, Size M). data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Flame retardant antistatic protective clothing.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Ph
---
Softening Point
---
Odor Threshold
---
Vapor Density
---
Relative Evaporation Rate
---
Flammability
---
Cloud Point
---
Colour Intensity
---
Voc Content
---
Partition Coefficient
---
Solidification Point
---
Odor
---
Vapor Pressure
---
Upper Explosive Limit
---
Decomposition Temperature
---
Metal Corrosion
---
Auto Ignition Temperature
---
Flash Point
79 °C - closed cup
Boiling Point
114 - 116 °C at 1 hPa - lit.
Bulk Density
---
Density
1,243 g/cm3 at 25 °C - lit.
Freezing Point
---
Evaporation Rate
---
Properties Status
---
Melting Point
---
Lower Explosive Limit
---
Dynamic Viscosity
---
Crystallisation Point
---
Molecular Weight
---
Relative Density
---
Solubility In Fat
---
Form
---
Solubility In Water
---
State Under Standard Conditions
---
Physical State Data
solid
Colour
---
Appearance
---
Physical State
solid
Kinematic Viscosity
---
Solubility
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical. The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents, strong reducing agents, alkalines, acids

Avoid

Strong heating.

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 5-(Hydroxymethyl)furfural?

The signal word is warning.

What is the physical form of 5-(Hydroxymethyl)furfural?

5-(Hydroxymethyl)furfural is a solid .

What is 5-(Hydroxymethyl)furfural used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for 5-(Hydroxymethyl)furfural?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.