Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Interflon Lube EP+ (Aerosol)
- Product Form
- Aerosol
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
lubricant
Manufacturers & Suppliers
Interflon BV
manufacturer
Belder 47, 4704 RK Roosendaal, Netherlands
+31 (0)165 553911
http://www.Interflon.com
Emergency Contacts
UK National Poison Centre
+44 870 600 6266
Mon - Fri 12:00 AM - 11:00 PM
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| butane EC: 203-448-7 | 106-97-8 | 10 - 25% | Yes |
| Propane EC: 200-827-9 | 74-98-6 | 10 - 25% | Yes |
| Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 918-481-9 | 64742-48-9 | 5 - 10% | Yes |
| Hydrocarbons, C7, n-alkanes, isoalkanes, cyclics EC: 927-510-4 | 64742-49-0 | 5 - 10% | Yes |
| Hydrocarbons, C6, isoalkanes, <5% n-hexane EC: 931-254-9 | 64742-49-0 | 5 - 10% | Yes |
| (Z)-N-methyl-N-(1-oxo-9-octa-decenyl)glycine EC: 203-749-3 | 110-25-8 | 1 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. In case of respiratory tract irritation, consult a physician. Provide fresh air.
Wash with plenty of soap and water.
Remove contact lenses, if present and easy to do. Continue rinsing. Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart.
Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting.
Immediate Medical Attention
In all cases of doubt, or when symptoms persist, seek medical advice. If breathing is irregular or stopped, immediately seek medical assistance. In case of respiratory tract irritation, consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water mist, Fire extinguishing powder
Water jet
In case of fire and/or explosion do not breathe fumes.
Co-ordinate firefighting measures to the fire surroundings. Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove persons to safety.
Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Place in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well-ventilated areas.
Store in accordance with local/regional/national/international regulations. Keep container tightly closed and in a well-ventilated place. Keep in a cool place.
Remove contaminated clothing and protective equipment before entering eating areas. Never place chemicals in containers that are normally used for food or drink.
Do not spray on an open flame or other ignition source.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only in well-ventilated areas.
Wear protective gloves. When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Type of material. NBR: acrylonitrile-butadiene rubber. CR: chloroprene (chlorobutadiene) rubber. PVC: polyvinyl chloride.
Use safety goggle with side protection.
In case of insufficient ventilation, wear suitable respiratory equipment. Type: A-P2 (combined filters against particles and organic gases and vapours, colour code: Brown/White).
Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended. Wash hands thoroughly after handling.
Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
See below 'Conditions to avoid'.
The mixture contains reactive substance(s). Risk of ignition.
No known hazardous reactions.
Do not spray on an open flame or other ignition source. Keep away from heat. Protect from sunlight.
Oxidisers
Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2
- Packing Group
- not assigned
Provisions for dangerous goods (ADR) should be complied within the premises.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Interflon Lube EP+ (Aerosol)?
The signal word is danger.
What is the physical form of Interflon Lube EP+ (Aerosol)?
Interflon Lube EP+ (Aerosol) is a liquid, gaseous (spray aerosol) with brown color. It has like oil odor.
What is Interflon Lube EP+ (Aerosol) used for?
lubricant
What are the hazard statements for Interflon Lube EP+ (Aerosol)?
This substance has 6 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: May burst if heated.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Interflon Lube EP+ (Aerosol)?
The melting point is not determined and the boiling point is <0 °C at 1,013 hPa.