NextSDS Logo
Safety Data Sheet EN

Maternal Screening Control, Level 1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Maternal Screening Control, Level 1
Product Code
MSS5024

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

RANDOX Laboratories Ltd. logo

RANDOX Laboratories Ltd.

manufacturer

55 Diamond Road, Crumlin, Co. Antrim, United Kingdom, BT29 4QY

+44 (0) 28 9442 2413

www.randox.com

Emergency Contacts

Emergency Contact

+44 (0) 28 9442 2413

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The control in this kit contains material of human origin.

For in vitro diagnostic use only. Do not pipette by mouth. Handle laboratory reagents in accordance with Good Laboratory Practice.

Notes

Each donor used in the preparation of the materials was tested by an FDA approved method for the presence of HIV and HCV antibodies, and the hepatitis B antigen, and found to be non-reactive. Reagents should be handled with the same care as a clinical specimen.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If breathing becomes difficult, call a physician.

Skin contact

In case of skin contact immediately wash skin with soap and copious quantities of water.

Eye contact

Flush with copious amounts of water for at least 15 minutes. Assure adequate flushing by separating eyelids with fingers. Call a physician.

Ingestion

If swallowed wash out mouth with water provided person is conscious, call a physician.

Immediate Medical Attention

Call a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Can use water, carbon dioxide, dry chemical or foam

Specific hazards

Not known

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Treat material as you would human body fluids. Ventilate area and wash spill site after material pick up is complete.

Cleanup methods

autoclaving at 121°C for 20 min. prior to appropriate disposal with regard to local regulations. Alternatively, decontamination using a 0.1% solution of sodium hypochlorite is acceptable.

Materials: No restriction

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

The normal precautions for handling chemicals must be observed. Avoid inhalation. Avoid contact with skin and do not swallow.

Storage

Store at temperatures and conditions as indicated on the product label.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves (rubber or plastic)

Eyes

Protective glasses

Skin/Body

Laboratory coat

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Lyophilised
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Pale yellow liquid when reconstituted
Colour Intensity
---
Form
---
Odor
Odourless
Odor Threshold
---
Ph
Not determined
Melting Point
Not determined
Boiling Point
Not determined
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
Not determined
Flammability
---
Upper Explosive Limit
Not determined
Lower Explosive Limit
Not determined
Explosive Limits
---
Auto Ignition Temperature
Not determined
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Not determined
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Avoid

Not determined

Incompatible

Not determined

Decomposition

None determined

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Maternal Screening Control, Level 1?

The signal word is no signal word.

What is the physical form of Maternal Screening Control, Level 1?

Maternal Screening Control, Level 1 is a lyophilised with pale yellow liquid when reconstituted color. It has odourless odor.

What is the melting point of Maternal Screening Control, Level 1?

The melting point is Not determined and the boiling point is Not determined.