NextSDS Logo
Safety Data Sheet EN

NEONATAL GAL-T Screening Fluo

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NEONATAL GAL-T Screening Fluo
Product Code
I-LU-288, I-LU-576

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For in vitro diagnostic use only

Manufacturers & Suppliers

L

LaCAR MDx technologies

manufacturer

Liège Science Park, Rue des Chasseurs Ardennais, 10, 4031 Angleur - Belgium

+32 (0) 4 287 39 44

Emergency Contacts

Emergency Contact

+1 703 527 3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Sens. Cat. 1A H317
Aquatic Acute Cat. 1
Aquatic Chronic Cat. 1
Resp. Sens. Cat. 1 H334
Acute Tox. Cat. 4 H302
Skin Irrit. Cat. 1 H314
Eye Dam. Cat. 1 H318
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H317 May cause an allergic skin reaction
H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapors/spray.
P280 Wear protective gloves/protective
P284 Wear respiratory protection
P303 + P361 + P353 IF ON SKIN (or hair): take off immediately all contaminated clothing. Rinse skin with water.
P501 Dispose of contents/container to an approved waste disposal plant.
IF INHALED: remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER / doctor if you feel unwell.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
ProClin™ 300 EC: 911-418-6 55965-84-9 0.05% Yes
G6PDH EC: 232-602-6 9001-40-5 10% Yes

Notes

Considering that G6PDH is contained in the calibrators and controls that are dried onto a filter paper card (Dried Blood Spot format), the danger of respiratory sensitization does not apply.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Fresh air. Call a physician.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water / shower. Call a physician immediately.

Eye contact

Rinse out with plenty of water. Remove contact lenses. Immediately call an ophthalmologist.

Ingestion

If swallowed: give water to drink (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise.

Immediate Medical Attention

Call a physician immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance no limitations of extinguishing agents are given.

Specific hazards

ProClin™ 300: Carbon oxides, Nitrogen oxides (NOx), Sulfur oxides, Hydrogen chloride gas, Combustible, Vapors are heavier than air and may spread along floors, Forms explosive mixtures with air on intense heating, Development of hazardous combustion gases or vapours possible in the event of fire. G6PDH: Nature of decomposition products not known, Combustible, Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert. Avoid inhalation of dusts.

Environmental

Do not let product enter drains.

Cleanup methods

Take up carefully. Clean up affected area.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

ProClin™ 300: Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols. G6PDH: Work under hood. Do not inhale substance/mixture.

Storage

ProClin™ 300: Tightly closed. G6PDH: Tightly closed. Dry. Keep locked up or in an area accessible only to qualified or authorized persons.

Hygiene

Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

ProClin™ 300: Full contact: Material: butyl-rubber, Minimum layer thickness: 0,3 mm, Break through time: 480 min, Material tested: Butoject® (KCL 897 / Aldrich Z677647, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 60 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). G6PDH: Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles

Respiratory

ProClin™ 300: Required when vapours/aerosols are generated. Recommended Filter type: Filter type ABEK. G6PDH: Required when dusts are generated. Recommended Filter type: Filter type P2. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.

Skin/Body

Protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid
Colour
Data no available
Colour Intensity
---
Form
Liquid
Odor
No data available
Odor Threshold
No data available
Ph
4.1 at 100 g/L
Melting Point
-40°C
Boiling Point
189°C
Flash Point
118°C – closed cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
---
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
Soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
58.8 mPa.s at 25°C
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The products are chemically stable under standard ambient conditions (room temperature).

Reactivity

ProClin™ 300: Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical. G6PDH: The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

No data available

Avoid

Strong heating

Incompatible

ProClin™ 300: Strong oxidizing agents, Reducing agents, Amines, Mercaptans; G6PDH: No data available

Decomposition

In the event of fire: see section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

No data available.

No data available.

12.2. Persistence and degradability

No data available.

No data available.

12.3. Bioaccumulative potential

No data available

No data available

12.4. Mobility in soil

No data available

No data available

12.5. Results of PBT and vPvB assessment

All the substances/mixtures contain no components considered to be either PBT or vPvB at levels of 0.1% or higher.

The substance/mixture does not contain components considered to be PBT or vPvB at levels of 0.1% or higher.

12.6. Other adverse effects

An environmental hazard cannot be excluded in the event of unprofessional handling or disposal. Components Modified alkyl carboxylate

An environmental hazard cannot be excluded in the event of unprofessional handling or disposal.

12.6. Other adverse effects

Mixture of 5-Chloro-2-methyl-4-isothiazolin-3-one and 2-Methyl-2H -isothiazol-3-one (3:1) Toxicity to fish: flow-through test LC50 - Oncorhynchus mykiss (rainbow trout) - 0,19 mg/l - 96 h (US-EPA) Toxicity to daphnia and other aquatic invertebrates: flow-through test LC50 - Daphnia magna (Water flea) - 0,18 mg/l - 48 h (US-EPA) Toxicity to bacteria static test: EC50 - activated sludge - 4,5 mg/l - 3 h (OECD Test Guideline 209)
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Product Disposal recommendations are based on material as supplied. Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3265
Shipping Name
CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S. (Mixture of 5-Chloro-2-methyl-4-isothiazolin-3-one and 2-Methyl-2H -isothiazol-3-one (3:1))
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This safety datasheet complies with the requirement of Regulation (EC) No 1907/2006.

Chemical Safety Assessment Not performed

Observe work restrictions regarding maternity protection in accordance to Dir 92/85/EEC or stricter national regulations where applicable. Take note of Dir 94/33/EC on the protection of young people at work.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NEONATAL GAL-T Screening Fluo?

The signal word is danger.

What is the physical form of NEONATAL GAL-T Screening Fluo?

NEONATAL GAL-T Screening Fluo is a liquid appearing as liquid with data no available color. It has no data available odor.

What is NEONATAL GAL-T Screening Fluo used for?

For in vitro diagnostic use only

What are the hazard statements for NEONATAL GAL-T Screening Fluo?

This substance has 2 hazard statements:

  • H317: May cause an allergic skin reaction
  • H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled

What is the melting point of NEONATAL GAL-T Screening Fluo?

The melting point is -40°C and the boiling point is 189°C.