Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Acetone HiPerSolv CHROMANORM® for HPLC
- Product Code
- 20067
- Synonyms
- 2-Propanone, Dimethyl ketone, DMK, Propanone
Regulatory Identifiers
- CAS Number
- 67-64-1 Check regulations →
- REACH No.
- 01-2119471330-49-XXXX
Identified Uses
General chemical reagent
Manufacturers & Suppliers
VWR International Ltd.
distributor
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN
0800 22 33 44
VWR
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetone | 67-64-1 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Call a POISON CENTRE/doctor. Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. In case of skin reactions, consult a physician.
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.
If accidentally swallowed rinse the mouth with plenty of water (only if the person is conscious) and obtain immediate medical attention. Do NOT induce vomiting. Give nothing to eat or drink.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, ABC-powder, Carbon dioxide (CO2), Nitrogen
no restriction
In case of fire may be liberated: Carbon monoxide, Carbon dioxide (CO2)
DO NOT fight fire when fire reaches explosives.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In case of major fire and large quantities: Remove persons to safety.
Discharge into the environment must be avoided.
Collect in closed and suitable containers for disposal.
Related Products
Similar products with comparable safety profiles
Acetone HiPerSolv CHROMANORM® for HPLC
CAS: 67-64-1
Chloroform HiPerSolv CHROMANORM® for HPLC
CAS: 67-66-3
Acetonitrile HiPerSolv CHROMANORM® for HPLC LC-MS grade - suitable for UPLC/UHPLC instruments
CAS: 75-05-8
Acetonitrile HiPerSolv CHROMANORM® for HPLC LC-MS grade - suitable for UPLC/UHPLC instruments
CAS: 75-05-8
Acetonitrile 50% / Water 47.5% / Trifluoroacetic acid 2.5% HiPerSolv CHROMANORM® Solution OS (Bruker Organic Solvent)
---
Xylene for GC-HS, ChromSolv®
CAS: 1330-20-7
Acetone AnalaR NORMAPUR® Reag. Ph. Eur., Reag. USP, ACS
CAS: 67-64-1
Chloroform, HPLC Grade
CAS: 67-66-3
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation, contact with eyes and skin. Keep away from sources of ignition - No smoking.
Keep container tightly closed and in a well-ventilated place.
Keep away from sources of ignition - No smoking. Usual measures for fire prevention. Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms EN ISO 374 In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact: Suitable material: CR (polychloroprene, chloroprene rubber), Thickness of the glove material: 0,75 mm, Breakthrough time: < 30 min, Recommended glove articles: VWR 112-2308. By long-term hand contact: Suitable material: Butyl caoutchouc (butyl rubber), Thickness of the glove material: 0,50 mm, Breakthrough time: > 480 min, Recommended glove articles: VWR 112-1570.
Eye glasses with side protection DIN-/EN-Norms DIN EN 166. Recommendation: VWR 111-0432
Respiratory protection necessary at: aerosol or mist formation. Suitable respiratory protection apparatus: Full-/half-/quarter-face masks (DIN EN 136/140). Recommendation: VWR 111-0206. Suitable material: AXP3. Recommendation: VWR 111-8932
Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapours are heavier than air, spread along floors and form explosive mixtures with air.
Formation of explosive mixtures with: Oxidising agent, strong, Reducing agent, strong, Nitric acid, Trichloromethane, Peroxides. Violent reaction with: Alkali (lye), Oxidising agent, Reducing agent. Exothermic reaction with: Bromine, Chlorine.
UV-radiation/sunlight, Heat. This material is combustible and can be ignited by heat, sparks, flames, or other sources of ignition (e.g. static electricity, pilot lights, or mechanical/electrical equipment).
Rubber articles, Plastic articles
no data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1090
- Shipping Name
- ACETONE
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Acetone HiPerSolv CHROMANORM® for HPLC known by?
Acetone HiPerSolv CHROMANORM® for HPLC is also known as: 2-Propanone, Dimethyl ketone, DMK, Propanone
What is the hazard signal word for Acetone HiPerSolv CHROMANORM® for HPLC?
The signal word is danger.
What is the physical form of Acetone HiPerSolv CHROMANORM® for HPLC?
Acetone HiPerSolv CHROMANORM® for HPLC is a liquid appearing as colourless with colourless color. It has characteristic odor.
What is Acetone HiPerSolv CHROMANORM® for HPLC used for?
General chemical reagent
What are the hazard statements for Acetone HiPerSolv CHROMANORM® for HPLC?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of Acetone HiPerSolv CHROMANORM® for HPLC?
The melting point is -95.4 °C and the boiling point is 56.2 °C (1013 hPa).