NextSDS Logo
Safety Data Sheet EN

Bondupal Heatresist black

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Bondupal Heatresist black

Regulatory Identifiers

CAS Number
N/A
UFI Code
PEAD-G8M8-P00T-DG59

Identified Uses

Coatings and paints, fillers, putties, thinners

Manufacturers & Suppliers

LÖRKEN-LACKE GMBH & CO. KG logo

LÖRKEN-LACKE GMBH & CO. KG

manufacturer

Clausenstr.37, D-42285 Wuppertal, Post-office box: 201139, D-42211 Wuppertal

+49 (0)202-24526-0

http://www.loerken-lacke.de

Emergency Contacts

Emergency Contact

+49 (0)202-24526-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapour.
H315 Causes skin irritation.
H319 Causes serious eye irritation.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P241 Use explosion-proof electrical/ventilating/lighting equipment.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
xylene EC: 215-535-7 1330-20-7 25 - 30% Yes
acetone; propan-2-one; propanone EC: 200-662-2 67-64-1 10 - 15% Yes
butan-1-ol; n-butanol EC: 200-751-6 71-36-3 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air. Medical treatment necessary. Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration.

Skin contact

After contact with skin, wash immediately with polyethylene glycol, followed by plenty of water. Take off immediately all contaminated clothing and wash it before reuse. Medical treatment necessary. Immediately remove any contaminated clothing, shoes or stockings. After contact with skin, wash immediately with plenty of water and soap.

Eye contact

After contact with the eyes, rinse with water with the eyelids open for a sufficient length of time, then consult an ophthalmologist immediately. In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical advice immediately.

Ingestion

Rinse mouth immediately and drink plenty of water. Induce vomiting when the affected person is not unconscious. Medical treatment necessary. If swallowed, rinse mouth with water (only if the person is conscious). Call a physician immediately. Put victim at rest, cover with a blanket and keep warm. Do NOT induce vomiting.

Symptoms: Observe risk of aspiration if vomiting occurs.

Immediate Medical Attention

Medical treatment necessary. Consult an ophthalmologist immediately. Call a physician immediately.

Medical Treatment

Medical treatment necessary.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray jet, Carbon dioxide (CO2), Foam, Extinguishing powder. alcohol resistant foam, Carbon dioxide (CO2), Extinguishing powder, Water mist

Unsuitable media

Full water jet

Specific hazards

Highly flammable. Vapours can form explosive mixtures with air. Burning produces heavy smoke.

Instructions

Use water spray jet to protect personnel and to cool endangered containers. Suppress gases/vapours/mists with water spray jet.

Firefighter Protection

Use appropriate respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Remove all sources of ignition. Provide adequate ventilation. Do not breathe gas/fumes/vapour/spray. Avoid contact with skin, eyes and clothes. Use personal protection equipment. Keep away from sources of ignition - No smoking. Ventilate affected area. Avoid breathing dust/fume/gas/mist/vapours/spray.

Environmental

Do not allow uncontrolled discharge of product into the environment.

Cleanup methods

Absorb with liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents). Collect in closed and suitable containers for disposal. Clean with detergents. Avoid solvent cleaners.

Materials: sand, diatomaceous earth, acid- or universal binding agents

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

If handled uncovered, arrangements with local exhaust ventilation have to be used. Do not breathe gas/fumes/vapour/spray. Avoid contact with skin, eyes and clothes. Avoid: Inhalation of vapours or spray/mists, Inhalation of dust/particles. When using do not eat, drink or smoke. Never use pressure to empty container. Keep/Store only in original container.

Storage

Keep container tightly closed in a cool, well-ventilated place. Protect from sunlight. Keep away from sources of ignition. Store in a place accessible by authorized persons only.

Hygiene

Remove contaminated, saturated clothing immediately. Draw up and observe skin protection programme. Wash hands and face before breaks and after work and take a shower if necessary. When using do not eat or drink.

Fire prevention

Keep away from sources of heat (e.g. hot surfaces), sparks and open flames. Keep away from sources of ignition - No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If handled uncovered, arrangements with local exhaust ventilation have to be used. Do not breathe gas/fumes/vapour/spray. Provide adequate ventilation. If handled uncovered, arrangements with local exhaust ventilation should be used if possible. If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn.

Hands

When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place concentration and quantity of hazardous substances. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Wear suitable gloves. Replace when worn. The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place concentration and quantity of hazardous substances. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. See information supplied by the manufacturer. Suitable material: Nitril 0,35 mm. Breakthrough time:: 480 min.

Eyes

Suitable eye protection: goggles.

Respiratory

In case of inadequate ventilation wear respiratory protection. Respiratory protection necessary at: exceeding exposure limit values. Use suitable breathing apparatus.

Skin/Body

Flame-retardant protective clothing. Wear anti-static footwear and clothing

Environmental

Do not allow to enter into surface water or drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
---
Cloud Point
---
Melting Point
not determined
Lower Explosive Limit
2,5 vol. %
Density
1,2837 g/cm³ DIN 53217
Ph
not determined
Physical State
Liquid
Voc Content
---
Dynamic Viscosity
---
Metal Corrosion
---
Properties Status
---
Kinematic Viscosity
---
Odor
characteristic
State Under Standard Conditions
---
Molecular Weight
---
Solidification Point
---
Boiling Point
136 °C
Partition Coefficient
not determined
Solubility
---
Form
---
Colour
black
Bulk Density
---
Appearance
---
Flash Point
-18 °C DIN 53213
Solubility In Water
The study does not need to be conducted because the substance is known to be insoluble in water.
Vapor Pressure
246 hPa (at 20 °C)
Relative Evaporation Rate
---
Decomposition Temperature
not determined
Auto Ignition Temperature
Solid: not applicable, Gas: not applicable
Solubility In Fat
---
Colour Intensity
---
Relative Density
---
Softening Point
---
Physical State Data
liquid
Odor Threshold
---
Evaporation Rate
not determined
Explosive Limits
---
Flammability
not applicable
Crystallisation Point
---
Freezing Point
---
Upper Explosive Limit
14,3 vol. %
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under storage at normal ambient temperatures.

Reactivity

Highly flammable.

Hazardous reactions

Exothermic reaction with: Oxidising agent, Strong acid, Strong alkali

Avoid

Keep away from sources of heat (e.g. hot surfaces), sparks and open flames. Vapours can form explosive mixtures with air.

Incompatible

No information available.

Decomposition

In case of warming: Formation of: Hazardous decomposition products

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
Paint
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Bondupal Heatresist black?

The signal word is danger.

What is the physical form of Bondupal Heatresist black?

Bondupal Heatresist black is a liquid with black color. It has characteristic odor.

What is Bondupal Heatresist black used for?

Coatings and paints, fillers, putties, thinners

What are the hazard statements for Bondupal Heatresist black?

This substance has 3 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

What is the melting point of Bondupal Heatresist black?

The melting point is not determined and the boiling point is 136 °C.