Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOD 607
- Product Code
- CH1325
- Chemical Name
- Alkaline-earth silicate wools (AES wools)
Regulatory Identifiers
- CAS Number
- 436083-99-7 Check regulations →
- REACH No.
- 01-2119457644-32-0000
Identified Uses
Application as high temperature processing, lining of industrial furnaces, thermal insulation of kilns, etc... (Please refer to specific technical data sheet for more information).
Manufacturers & Suppliers
Morgan ThermalCeramics
manufacturer
THERMAL CERAMICS
manufacturer
Route de Lauterbourg - BP 90148 67163 WISSEMBOURG Cedex
+33 (0)3 88 54 95 50
http://www.thermalceramics.com
THERMAL CERAMICS LIMITED
manufacturer
Tebay Road, Bromborough Wirral, Merseyside CH62 3PH
+44 (0) 151 334 4030
http://www.thermalceramics.com
Emergency Contacts
Emergency Contact
+44 (0) 7931 963 973
Only available during office hours
EN
Emergency Contact
+33 (0) 6 07 42 97 74
Only available during office hours
FR, DE
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Cement | 65997-15-1 | 20 - 50% | Yes |
| Alkaline-earth silicate wools | 436083-99-7 | 5 - 35% | No |
| Clay EC: 215-108-5 | --- | 10 - 70% | No |
| Calcium oxide EC: 235-253-8 | 1305-78-8 | 5% | No |
| Other inert material | --- | 1% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to a dust free area, drink water and blow nose.
Symptoms: Irritation of nose and throat.
If this occurs, rinse affected areas with water and wash gently. Do not rub or scratch exposed skin.
Symptoms: mild mechanical temporary skin irritation
In case of eye contact flush abundantly with water. Do not rub eyes.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing agent suitable for surrounding combustible materials.
Packaging and surrounding materials may be combustible
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Restore the situation to normal as quickly as possible.
Do not flush spillage to drain and prevent from entering natural watercourses. Check for local regulations, which may apply.
If brushing is used, ensure that the area is wetted down first.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use appropriate gloves and safety glasses for basic substances. The process or processes should be designed to limit the amount of handling.
Store in original packaging in a dry area. Always use sealed and clearly labelled containers. Avoid damaging containers.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Review your applications in order to identify potential sources of dust exposure. If necessary, conduct personal air monitoring. Use technical and/or organisational means to comply with regulations. In case of higher concentrations or where the concentration is not known, please seek advice from your company and/or local Thermal Ceramics' supplier. Identify and use operating procedures, which will limit dust production and exposure of workers. If necessary consult an industrial hygienist to design proper workplace controls.
Use of gloves and work clothes is recommended.
As necessary wear goggles or safety glasses with side shields.
For dust concentrations below the exposure limit value, RPE is not required but FFP2 respirators may be used on a voluntary basis. For short-term operations where excursions are less than ten times the limit value use FFP3 respirators. In case of higher concentrations or where the concentration is not known, please seek advice from your company and/or local Thermal Ceramics' supplier.
Use of gloves and work clothes is recommended. Soiled clothes should be cleaned before being taken off (e.g. use vacuum cleaning, not compressed air).
Refer to local, national or European applicable environmental standards for release to air, water and soil. For waste, refer to Section 13.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
These products are stable
These products harden in presence of water.
Please refer to handling and storage advice section 7
Continuous use of these products at temperature above 900°C may lead to the formation of several crystalline phases.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Ensure that dust is not windblown during transportation.
Ensure that dust is not windblown during transportation.
Ensure that dust is not windblown during transportation.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOD 607?
The signal word is no signal word.
What is the physical form of LOD 607?
LOD 607 is a solid appearing as grey powder with fibrous material .
What is the solubility of LOD 607?
Less than 1 mg/l
What is LOD 607 used for?
Application as high temperature processing, lining of industrial furnaces, thermal insulation of kilns, etc... (Please refer to specific technical data sheet for more information).
What is the melting point of LOD 607?
The melting point is >1400°C and the boiling point is Not applicable.