01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ST 03003 LD

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Plastic additive, SU3 Industrial uses, SU12 Manufacture of plastics products, PC32 Polymer preparations and compounds, PROC5, PROC6, PROC8a, PROC14, PROC23, ERC3, ERC5, AC13

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

C

CONSTAB Polyolefin Additives GmbH

manufacturer

Industriestrasse Möhnetal 16, D-59602 Rüthen

+49(0)2952/819-0

Emergency Contacts

CONSTAB Polyolefin Additives GmbH

+49(0)2952-819-0

8:00-16:00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Plastic additive

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

After contact with the molten product, cool rapidly with cold water. Do not pull solidified product off the skin.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor. A person vomiting while laying on their back should be turned onto their side.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Unsuitable media

Water with full jet

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

Wear self-contained respiratory protective device. Wear fully protective suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Particular danger of slipping on leaked/spilled product.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Store in cool, dry place in tightly closed receptacles. Keep away from heat and direct sunlight. Ensure good ventilation/exhaustion at the workplace. Prevent formation of dust.

Storage

Store in a cool location. Store only in the original receptacle. Store in cool, dry conditions in well sealed receptacles. Protect from contamination.

Fire prevention

Keep ignition sources away - Do not smoke. Protect from heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Not necessary if room is well-ventilated.

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
Undetermined.
Auto Ignition Temperature
Product is not selfigniting.
Partition Coefficient
Not determined.
State Under Standard Conditions
---
Softening Point
---
Solubility
---
Density
Not determined.
Colour
According to product specification
Voc Content
---
Cloud Point
---
Relative Density
Not determined.
Relative Evaporation Rate
---
Vapor Density
Not applicable.
Molecular Weight
---
Crystallisation Point
---
Decomposition Temperature
Not determined.
Freezing Point
Undetermined.
Form
Granulate
Physical State
Solid
Flash Point
Not applicable.
Odor Threshold
Not determined.
Properties Status
---
Physical State Data
solid
Solidification Point
---
Colour Intensity
---
Explosive Limits
---
Metal Corrosion
Void
Appearance
Granulate
Upper Explosive Limit
Not determined.
Solubility In Fat
---
Evaporation Rate
Not applicable.
Bulk Density
---
Kinematic Viscosity
Not applicable.
Melting Point
Undetermined.
Flammability
Not determined.
Lower Explosive Limit
Not determined.
Ph
Not applicable.
Solubility In Water
Insoluble.
Dynamic Viscosity
Not applicable.
Vapor Pressure
Not applicable.
Odor
Product specific
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications. No decomposition if used and stored according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

Reacts with strong acids and oxidising agents.

Avoid

No further relevant information available.

Incompatible

Reacts with strong acids and oxidising agents.

Decomposition

Poisonous gases/vapours, Carbon monoxide and carbon dioxide, Phosphorus oxides (e.g. P2O5)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

Disposal

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
not regulated
Shipping Name
not regulated
Transport Class
not regulated
Packing Group
not regulated
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ST 03003 LD?

The signal word is no signal word.

What is the physical form of ST 03003 LD?

ST 03003 LD is a solid appearing as granulate with according to product specification color. It has product specific odor.

What is ST 03003 LD used for?

Plastic additive, SU3 Industrial uses, SU12 Manufacture of plastics products, PC32 Polymer preparations and compounds, PROC5, PROC6, PROC8a, PROC14, PROC23, ERC3, ERC5, AC13

What is the melting point of ST 03003 LD?

The melting point is Undetermined. and the boiling point is Undetermined..