Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- KORRO 60-9
- Product Code
- 00029609
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 2Q54-30MA-P00A-K6WS
Identified Uses
Product categories [PC]: PC25 - Metal working fluids, Sector of uses [SU]: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites, Environmental release categories [ERC]: ERC4 - Industrial use of processing aids in processes and products, not becoming part of articles
Manufacturers & Suppliers
Graf Technik GmbH
manufacturer
Max-Eyth-Strasse 23, D – 70736 Fellbach
+49 711 – 633447-0
http://www.graf-technik.de
Emergency Contacts
Emergency Contact
+49 711 – 633447-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Diethylene glycol EC: 203-872-2 | 111-46-6 | 50 - 75% | Yes |
| Triethanolamine EC: 203-049-8 | 102-71-6 | 1 - 3% | No |
| Boric acid (H3BO3) EC: 233-139-2 | 10043-35-3 | 1 - 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air.
Wash skin with soap and water. In the case of skin irritation or allergic reactions see a physician.
Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Consult a physician.
Do NOT induce vomiting. Rinse mouth. Never give anything by mouth to an unconscious person. Call a physician.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Large Fire: CAUTION: Use of water spray when fighting fire may be inefficient.
Do not scatter spilled material with high pressure water streams.
No information available.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation.
See Section 12 for additional Ecological Information.
Take up mechanically, placing in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product. Remove contaminated clothing and shoes.
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep out of the reach of children. Store locked up.
Do not eat, drink or smoke when using this product. Wash hands before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
None under normal use conditions.
Wear suitable gloves. NBR (Nitrile rubber), 0.5 mm, >=480 min.
If splashes are likely to occur, wear safety glasses with side-shields.
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required. Recommended Filter Type: Filtering device (full mask or mouthpiece) with filter: A-P2
Wear suitable protective clothing.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No information available.
None under normal processing.
None known based on information supplied.
None known based on information supplied.
None known based on information supplied.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for KORRO 60-9?
The signal word is danger.
What is the physical form of KORRO 60-9?
KORRO 60-9 is a liquid appearing as liquid with red color. It has characteristic odor.
What is KORRO 60-9 used for?
Product categories [PC]: PC25 - Metal working fluids, Sector of uses [SU]: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites, Environmental release categories [ERC]: ERC4 - Industrial use of processing aids in processes and products, not becoming part of articles
What are the hazard statements for KORRO 60-9?
This substance has 2 hazard statements:
- H302: Harmful if swallowed.
- H360FD: May damage fertility. May damage the unborn child.
What is the melting point of KORRO 60-9?
The melting point is Not established and the boiling point is Not established.