Silicone Viscosity Standards

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Silicone Viscosity Standards
Product Code
9727-Z10, 9727-Z14, 9727-Z18, 9727-Z22, 9727-Z26, 9727-Z30, 9727-Z34, 9727-Z38, 9727-Z42, 9727-Z46, 9727-Z50
Synonyms
RT5, RT10, RT50, RT100, RT500, RT1000, RT5000, RT12500, RT30000, RT60000, RT100000, Dow Corning 200® Fluids

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Rotational viscometer viscosity calibration standards

Manufacturers & Suppliers

C

Cannon Instrument Company

manufacturer

2139 High Tech Road, State College, Pennsylvania 16803

(814) 353-8000

Emergency Contacts

CHEM-TEL Inc.

(800) 255-3924

CHEM-TEL Inc.

+1 (813) 248-0585

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

None present. This is not a hazardous substance as defined in the OSHA Hazard Communication Standard

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No first aid should be needed

Skin contact

No first aid should be needed

Eye contact

Immediately flush with water

Ingestion

No first aid should be needed

Medical Treatment

Treat symptomatically

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

On large fires, use dry chemical, foam or water spray. On small fires, use carbon dioxide (CO2), dry chemical or water spray. Water can be used to cool fire exposed containers

Specific hazards

Unusual fire hazards: None identified

Instructions

Self-contained breathing apparatus and protective clothing should be worn in fighting large fires involving chemicals. Determine the need to evacuate or isolate the area according to your local emergency plan. Use water spray to keep the exposed containers cool.

Firefighter Protection

Self-contained breathing apparatus and protective clothing should be worn in fighting large fires involving chemicals.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Determine whether to evacuate or isolate the area according to your local emergency plan.

Large spill

For large spills, provide diking or other appropriate containment to keep material from spreading. If diked material can be pumped, store recovered material in an appropriate container.

Cleanup methods

Clean up remaining materials from spill with suitable absorbent. Clean area as appropriate. Final cleaning may require the use of steam, solvents or detergents.

Materials: suitable absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use with adequate ventilation

Storage

Use reasonable care and store away from oxidizing materials

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

General ventilation is recommended. No local exhaust ventilation should be needed

Hands

No special protection needed

Eyes

Use proper protection – safety glasses as a minimum

Respiratory

No respiratory protection should be needed

Skin/Body

Any specific clothing information provided is based on published literature or manufacturer data. The types of clothing to be considered for this material include:

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
not available
Decomposition Temperature
---
Form
Liquid
Colour Intensity
---
State Under Standard Conditions
---
Crystallisation Point
---
Metal Corrosion
---
Relative Density
0.915 (lowest viscosity grade) to 0.97 (higher viscosity grades)
Properties Status
---
Odor
odorless (lower viscosity grades) to characteristic odor
Physical State
Liquid
Kinematic Viscosity
5 cSt to 100,000 cSt – see product specification for each grade
Solidification Point
---
Density
not available
Cloud Point
---
Melting Point
not available
Freezing Point
not available
Bulk Density
not available
Solubility In Water
not available
Flash Point
101 °C (214 °F) to 321 °C (610 °F) [Closed Cup]
Upper Explosive Limit
not available
Explosive Limits
---
Solubility
---
Vapor Density
not available
Vapor Pressure
not available
Auto Ignition Temperature
not available
Solubility In Fat
---
Colour
Colorless
Relative Evaporation Rate
---
Physical State Data
liquid
Flammability
---
Lower Explosive Limit
not available
Evaporation Rate
not available
Voc Content
---
Boiling Point
>35 °C (>95 °F) to >273 °C (>523 °F) for 100,000 cSt grade
Appearance
Colorless
Softening Point
---
Partition Coefficient
---
Ph
not available
Dynamic Viscosity
---
Odor Threshold
not available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Hazardous reactions

Hazardous polymerization will not occur

Incompatible

Oxidizing materials can cause a reaction

Decomposition

Formaldehyde may be formed at elevated temperatures. See section 6.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Silicone Viscosity Standards known by?

Silicone Viscosity Standards is also known as: RT5, RT10, RT50, RT100, RT500, RT1000, RT5000, RT12500, RT30000, RT60000, RT100000, Dow Corning 200® Fluids

What is the hazard signal word for Silicone Viscosity Standards?

The signal word is no signal word.

What is the physical form of Silicone Viscosity Standards?

Silicone Viscosity Standards is a liquid appearing as colorless with colorless color. It has odorless (lower viscosity grades) to characteristic odor odor.

What is Silicone Viscosity Standards used for?

Rotational viscometer viscosity calibration standards

What is the melting point of Silicone Viscosity Standards?

The melting point is not available and the boiling point is >35 °C (>95 °F) to >273 °C (>523 °F) for 100,000 cSt grade.