Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- General Purpose Viscosity Standards
- Product Code
- 9727-G22, 9727-G45
- Chemical Name
- Hydrocarbon liquid mixture of n-decane and tetradecane or petroleum oil
- Synonyms
- N2, N2B
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Viscometer calibration standard
Manufacturers & Suppliers
Cannon Instrument Company
manufacturer
2139 High Tech Road, State College, Pennsylvania 16803
(814) 353-8000
Emergency Contacts
CHEM-TEL Inc.
(800) 255-3924
24-Hour
CHEM-TEL Inc.
+1 (813) 248-0585
24-Hour
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbon liquid | --- | --- | Yes |
Notes
This product is hazardous as defined in 29 CFR1910.1200, based on the following:
First Aid Measures
Emergency procedures for chemical exposure incidents
Using proper respiratory protection, immediately remove the affected victim from exposure. Administer artificial respiration if breathing is stopped. Keep at rest. Call for prompt medical attention.
Flush with large amounts of water; use soap if available. Remove grossly contaminated clothing, including shoes, and launder before reuse.
Flush eyes with large amounts of water until irritation subsides. If irritation persists, get medical attention.
Symptoms: irritation
If swallowed, DO NOT induce vomiting. Keep at rest. Get prompt medical attention.
Immediate Medical Attention
Call for prompt medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide, foam, dry chemical and water fog.
Avoid spraying water directly into storage containers due to danger of boilover.
This liquid is volatile and gives off invisible vapors. Either the liquid or vapor may settle in low areas or travel some distance along the ground or surface to ignition sources where they may ignite or explode. Combustible Liquid can form combustible mixtures at temperatures at or above the flashpoint.
Use water spray to cool fire exposed surfaces and to protect personnel. Isolate "fuel" supply from fire. Use foam, dry chemical, or water spray to extinguish fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Shut off source taking normal safety precautions. Take measures to minimize the effects on ground water. Recover by pumping (use an explosion proof or hand pump) or contain spilled material with sand or other suitable absorbent and remove mechanically into containers.
No respiratory protection should be needed for small spills.
For large spills, use self-contained breathing apparatus or air-purifying respiratory protection according to established local/ site emergency response procedures.
Prevent material from entering sewers, water sources or low lying areas; advise the relevant authorities if it has, or if it contaminates soil/vegetation.
Recover by pumping (use an explosion proof or hand pump) or contain spilled material with sand or other suitable absorbent and remove mechanically into containers.
Materials: sand or other suitable absorbent
Related Products
Similar products with comparable safety profiles
General Purpose Viscosity Standards
---
General Purpose Viscosity Standard – Synthetic Base Oil
---
Silicone Viscosity Standards
---
Viscosity Reference Standard General Purpose Type S3, UKAS ISO 17025 / ISO 17034, 500 mL / AP Dual-branded
UFI: HJ25-X0AK-600X-NY9E
Viscosity Reference Standard General Purpose Type N26, UKAS ISO 17025 / ISO 17034, 500 mL / AP Dual-branded
UFI: KH45-K06Q-800A-VTPW
Viscosity Reference Standard General Purpose Type N7.5, UKAS ISO 17025 / ISO 17034, 500 mL / AP Dual-branded
UFI: A095-W03C-6002-8K08
Viscosity Reference Standard General Purpose Type N415, UKAS ISO 17025 / ISO 17034, 500 mL / AP Dual-branded
---
Silicone Viscosity Standards (5 cSt to 100,000 cSt)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep container closed. Handle and open containers with care.
Keep containers closed when not in use. Do not store in open or unlabelled containers. Store in a cool, well ventilated place, away from strong oxidizing agents and combustible materials.
Do not store near heat, sparks, flame or strong oxidants. Use proper bonding and/or grounding procedure.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The use of local exhaust ventilation is recommended to control process emissions near the source. Laboratory samples should be handled in a lab hood. Provide mechanical ventilation of confined spaces. See respiratory protection recommendations.
chemical resistant gloves
Use proper protection – safety glasses as a minimum. For open systems where contact is likely, wear safety glasses with side shields. Where contact may occur, wear safety glasses with side shields.
Where concentrations in air may exceed the limits given in this Section and engineering, work practice or other means of exposure reduction are not adequate, NIOSH approved respirators may be necessary to prevent overexposure by inhalation.
wear long sleeves, protective clothing and footwear
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
Hazardous polymerization will not occur
Extreme heat and high energy sources of ignition.
Halogens, molten sulfur, strong oxidizing agents.
Product does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is General Purpose Viscosity Standards known by?
General Purpose Viscosity Standards is also known as: N2, N2B
What is the hazard signal word for General Purpose Viscosity Standards?
The signal word is no signal word.
What is the physical form of General Purpose Viscosity Standards?
General Purpose Viscosity Standards is a liquid with clear colorless color. It has characteristic petroleum odor odor.
What is General Purpose Viscosity Standards used for?
Viscometer calibration standard
What is the melting point of General Purpose Viscosity Standards?
The melting point is not determined and the boiling point is not determined.