NextSDS Logo
Safety Data Sheet EN

General Purpose Viscosity Standards

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
General Purpose Viscosity Standards
Product Code
9727-G22, 9727-G45
Chemical Name
Hydrocarbon liquid mixture of n-decane and tetradecane or petroleum oil
Synonyms
N2, N2B

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Viscometer calibration standard

Manufacturers & Suppliers

C

Cannon Instrument Company

manufacturer

2139 High Tech Road, State College, Pennsylvania 16803

(814) 353-8000

Emergency Contacts

CHEM-TEL Inc.

(800) 255-3924

24-Hour

CHEM-TEL Inc.

+1 (813) 248-0585

24-Hour

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Eye: Irritant
Skin: Irritant; can be absorbed through the skin

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Hydrocarbon liquid --- --- Yes

Notes

This product is hazardous as defined in 29 CFR1910.1200, based on the following:

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Using proper respiratory protection, immediately remove the affected victim from exposure. Administer artificial respiration if breathing is stopped. Keep at rest. Call for prompt medical attention.

Skin contact

Flush with large amounts of water; use soap if available. Remove grossly contaminated clothing, including shoes, and launder before reuse.

Eye contact

Flush eyes with large amounts of water until irritation subsides. If irritation persists, get medical attention.

Symptoms: irritation

Ingestion

If swallowed, DO NOT induce vomiting. Keep at rest. Get prompt medical attention.

Immediate Medical Attention

Call for prompt medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide, foam, dry chemical and water fog.

Unsuitable media

Avoid spraying water directly into storage containers due to danger of boilover.

Specific hazards

This liquid is volatile and gives off invisible vapors. Either the liquid or vapor may settle in low areas or travel some distance along the ground or surface to ignition sources where they may ignite or explode. Combustible Liquid can form combustible mixtures at temperatures at or above the flashpoint.

Instructions

Use water spray to cool fire exposed surfaces and to protect personnel. Isolate "fuel" supply from fire. Use foam, dry chemical, or water spray to extinguish fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Shut off source taking normal safety precautions. Take measures to minimize the effects on ground water. Recover by pumping (use an explosion proof or hand pump) or contain spilled material with sand or other suitable absorbent and remove mechanically into containers.

Small spill

No respiratory protection should be needed for small spills.

Large spill

For large spills, use self-contained breathing apparatus or air-purifying respiratory protection according to established local/ site emergency response procedures.

Environmental

Prevent material from entering sewers, water sources or low lying areas; advise the relevant authorities if it has, or if it contaminates soil/vegetation.

Cleanup methods

Recover by pumping (use an explosion proof or hand pump) or contain spilled material with sand or other suitable absorbent and remove mechanically into containers.

Materials: sand or other suitable absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container closed. Handle and open containers with care.

Storage

Keep containers closed when not in use. Do not store in open or unlabelled containers. Store in a cool, well ventilated place, away from strong oxidizing agents and combustible materials.

Fire prevention

Do not store near heat, sparks, flame or strong oxidants. Use proper bonding and/or grounding procedure.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The use of local exhaust ventilation is recommended to control process emissions near the source. Laboratory samples should be handled in a lab hood. Provide mechanical ventilation of confined spaces. See respiratory protection recommendations.

Hands

chemical resistant gloves

Eyes

Use proper protection – safety glasses as a minimum. For open systems where contact is likely, wear safety glasses with side shields. Where contact may occur, wear safety glasses with side shields.

Respiratory

Where concentrations in air may exceed the limits given in this Section and engineering, work practice or other means of exposure reduction are not adequate, NIOSH approved respirators may be necessary to prevent overexposure by inhalation.

Skin/Body

wear long sleeves, protective clothing and footwear

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Clear colorless
Colour Intensity
---
Form
Liquid
Odor
Characteristic petroleum odor
Odor Threshold
not available
Ph
not applicable
Melting Point
not determined
Boiling Point
not determined
Flash Point
>~149°F/65°C (minimum)
Freezing Point
not determined
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
not determined
Vapor Pressure
not determined
Vapor Density
Greater than air
Relative Density
Lighter than water
Bulk Density
Not available
Density
Not available
Flammability
not determined
Upper Explosive Limit
not determined
Lower Explosive Limit
not determined
Explosive Limits
---
Auto Ignition Temperature
not determined
Decomposition Temperature
---
Solubility
---
Partition Coefficient
not determined
Solubility In Water
negligible
Solubility In Fat
---
Molecular Weight
not determined
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Hazardous reactions

Hazardous polymerization will not occur

Avoid

Extreme heat and high energy sources of ignition.

Incompatible

Halogens, molten sulfur, strong oxidizing agents.

Decomposition

Product does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is General Purpose Viscosity Standards known by?

General Purpose Viscosity Standards is also known as: N2, N2B

What is the hazard signal word for General Purpose Viscosity Standards?

The signal word is no signal word.

What is the physical form of General Purpose Viscosity Standards?

General Purpose Viscosity Standards is a liquid with clear colorless color. It has characteristic petroleum odor odor.

What is General Purpose Viscosity Standards used for?

Viscometer calibration standard

What is the melting point of General Purpose Viscosity Standards?

The melting point is not determined and the boiling point is not determined.