NextSDS Logo
Safety Data Sheet EN

Torch Coolant 30% PG Mixture

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Torch Coolant 30% PG Mixture
Product Code
028872, 428839

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coolant/ Cutting solution

Uses advised against

No relevant information available.

Manufacturers & Suppliers

Hypertherm logo

Hypertherm

manufacturer

21 Great Hollow Road, Hanover, NH 03755 USA

+1 (603) 643-5638

http://www.hypertherm.com

H

Hypertherm

manufacturer

Laan van Kopenhagen 100, 3317 DM Dordrecht Netherlands

+31 (0) 88 497 3727

Emergency Contacts

ChemTel Inc.

(800)255-3924

ChemTel Inc.

+1 (813)248-0585

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Chemical characterization: Mixtures

Chemical Name CAS Number Concentration Hazardous
Propylene Glycol 57-55-6 25 - 50% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Rinse with warm water. If skin irritation is experienced, consult a doctor.

Eye contact

Remove contact lenses if worn. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Rinse out mouth and then drink plenty of water. Do not induce vomiting; immediately call for medical help.

Symptoms: Gastric or intestinal disorders when ingested.

Immediate Medical Attention

Immediately call for medical help.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Unsuitable media

None.

Specific hazards

No relevant information available.

Firefighter Protection

Wear self-contained respiratory protective device. Wear fully protective suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Particular danger of slipping on leaked/spilled product.

Environmental

Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent formation of aerosols. Avoid splashes or spray in enclosed areas.

Storage

Store in a cool location. Keep containers tightly sealed.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No relevant information available.

Hands

Gloves are advised for repeated or prolonged contact. Wear protective gloves to handle contents of damaged or leaking units. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.

Eyes

Safety glasses. Follow relevant national guidelines concerning the use of protective eyewear.

Respiratory

Not required under normal conditions of use. For spills, respiratory protection may be advisable.

Skin/Body

Not required under normal conditions of use.

Environmental

No special requirements.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid, Pink, Light red
Colour
Pink, Light red
Colour Intensity
---
Form
Liquid
Odor
Slight.
Odor Threshold
Not determined.
Ph
6
Melting Point
Not determined.
Boiling Point
>100 °C (>212 °F)
Flash Point
>95 °C (>203 °F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
1.0 ± 0.1 g/cm³ (8.345 ± 0.835 lbs/gal)
Bulk Density
---
Density
---
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Not determined.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

No relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used and stored according to specifications.

Incompatible

Strong oxidizers, strong acids and strong bases.

Decomposition

Carbon Monoxide, Carbon Dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Aquatic toxicity: No relevant information available.

No relevant information available regarding aquatic toxicity.

Persistence and degradability

No relevant information available.

No relevant information available.

Bioaccumulative potential

No relevant information available.

No relevant information available.

Mobility in soil

No relevant information available.

Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

The substance is not considered to be PBT or vPvB.

Other adverse effects

No relevant information available.

No relevant information available.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The user of this material has the responsibility to dispose of unused material, residues and containers in compliance with all relevant local, state and federal laws and regulations regarding treatment, storage and disposal for hazardous and nonhazardous wastes.

Disposal

The user of this material has the responsibility to dispose of unused material, residues and containers in compliance with all relevant local, state and federal laws and regulations regarding treatment, storage and disposal for hazardous and nonhazardous wastes.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Torch Coolant 30% PG Mixture?

The signal word is no signal word.

What is the physical form of Torch Coolant 30% PG Mixture?

Torch Coolant 30% PG Mixture is a liquid appearing as liquid, pink, light red with pink, light red color. It has slight. odor.

What is Torch Coolant 30% PG Mixture used for?

Coolant/ Cutting solution

What is the melting point of Torch Coolant 30% PG Mixture?

The melting point is Not determined. and the boiling point is >100 °C (>212 °F).