Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Torch Coolant 30% PG Mixture
- Product Code
- 028872, 428839
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Coolant/ Cutting solution
Uses advised against
No relevant information available.
Manufacturers & Suppliers
Hypertherm
manufacturer
21 Great Hollow Road, Hanover, NH 03755 USA
+1 (603) 643-5638
http://www.hypertherm.com
Hypertherm
manufacturer
Laan van Kopenhagen 100, 3317 DM Dordrecht Netherlands
+31 (0) 88 497 3727
Emergency Contacts
ChemTel Inc.
(800)255-3924
ChemTel Inc.
+1 (813)248-0585
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Chemical characterization: Mixtures
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Propylene Glycol | 57-55-6 | 25 - 50% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse with warm water. If skin irritation is experienced, consult a doctor.
Remove contact lenses if worn. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Rinse out mouth and then drink plenty of water. Do not induce vomiting; immediately call for medical help.
Symptoms: Gastric or intestinal disorders when ingested.
Immediate Medical Attention
Immediately call for medical help.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
None.
No relevant information available.
Firefighter Protection
Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Particular danger of slipping on leaked/spilled product.
Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Welding Torch - Coolant
---
Coolant VCS ready mixed mix 40/60
---
B PG COOLANT
UFI: 878V-2566-C995-CP34
Cat® ELC™ (Extended Life Coolant) Premix 50/50
---
MPM Coolant Premium Longlife -40°C G13 Ready to Use
UFI: QSKQ-5GAP-320Q-7KES
Bobcat Propylene Glycol Antifreeze & Coolant Premix
---
EG COOLANT
---
Kroon-Oil Coolant -26
UFI: MV60-20NA-S00G-M4X4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent formation of aerosols. Avoid splashes or spray in enclosed areas.
Store in a cool location. Keep containers tightly sealed.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No relevant information available.
Gloves are advised for repeated or prolonged contact. Wear protective gloves to handle contents of damaged or leaking units. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Safety glasses. Follow relevant national guidelines concerning the use of protective eyewear.
Not required under normal conditions of use. For spills, respiratory protection may be advisable.
Not required under normal conditions of use.
No special requirements.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
No relevant information available.
No dangerous reactions known.
No decomposition if used and stored according to specifications.
Strong oxidizers, strong acids and strong bases.
Carbon Monoxide, Carbon Dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Torch Coolant 30% PG Mixture?
The signal word is no signal word.
What is the physical form of Torch Coolant 30% PG Mixture?
Torch Coolant 30% PG Mixture is a liquid appearing as liquid, pink, light red with pink, light red color. It has slight. odor.
What is Torch Coolant 30% PG Mixture used for?
Coolant/ Cutting solution
What is the melting point of Torch Coolant 30% PG Mixture?
The melting point is Not determined. and the boiling point is >100 °C (>212 °F).