Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1
- Product Code
- 1304684
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Epoxy resin
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Epichlorohydrin-4,4'-isopropylidene diphenol resin | 25068-38-6 | 80 - 100% | Yes |
| butyl glycidyl ether | 2426-08-6 | 10 - 30% | Yes |
| Titanium dioxide | 13463-67-7 | 0.1 - 1% | Yes |
| Bisphenol-F Epichlorhydrin resin | 9003-36-5 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. If symptoms develop and persist, get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
In case of fire, keep containers cool with water spray. May decompose above 149°C (300°F). May polymerize above 260°C (500°F) in which case closed containers may rupture or explode. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Ensure adequate ventilation. Wear appropriate personal protective equipment. Refer to Section 8 "Exposure Controls / Personal Protection" prior to clean up. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE PC 9410 AGGREGATE known as Fixmaster® Magna-Crete® 95551
---
LOCTITE PC 7257 B known as LOCTITE FIXMAST MAGROUT 5GA PTB
---
LOCTITE PC 7257 known as LOCTITE FIX MAGNACRETE SS
---
LOCTITE PC 7257 B known as LOCTITE FIXMAST MAGROUT 1GA PTB
---
LOCTITE SF 8220 known as LOCTITE FIXMASTER FLEX CLEANER
---
LOCTITE EA 7363 B known as FIXMASTER ANC BLT GRT HP 4.5OZB
---
LOCTITE PC 7222 known as Fixmaster Wear Resistant Putty
---
LOCTITE PC 7222 known as Fixmaster Wear Resist Putty
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Use only with adequate ventilation. Keep container closed.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame. Protect from direct sunlight.
Wash thoroughly after handling.
Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight.
Strong oxidizing agents. Strong acids and strong bases. Strong Lewis acids. Strong mineral acids. Amines.
Oxides of carbon. Aldehydes. Acids. Phenolics. Toxic fumes. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (Bisphenol-A Epichlorhydrin resin)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1?
The signal word is warning.
What is the physical form of LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1?
LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1 is a liquid with gray / grey color. It has sweet odor.
What is the solubility of LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1?
Insoluble Water
What is LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1 used for?
Epoxy resin
What are the hazard statements for LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1?
This substance has 6 hazard statements:
- H227: COMBUSTIBLE LIQUID.
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H341: SUSPECTED OF CAUSING GENETIC DEFECTS.
- H361: SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.
What is the melting point of LOCTITE PC 7307 CONCRETE SEALER known as FIXMASTER CONCRETE SEALER 1?
The melting point is Not applicable, Product is a liquid and the boiling point is > 250 °C (> 482°F).