Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC
- Product Code
- 28354
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Silicone sealant
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isobornyl acrylate | 5888-33-5 | 1 - 5% | Yes |
| 2,2-Diethoxyacetophenone | 6175-45-7 | 1 - 5% | Yes |
| Trimethoxyvinylsilane | 2768-02-7 | 1 - 5% | Yes |
| N,N-Dimethylacrylamide | 2680-03-7 | 1 - 5% | Yes |
Non hazardous components: Actual concentration or concentration range is withheld as a trade secret.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air.
Immediately flush skin with plenty of water (using soap, if available). Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Do not induce vomiting.
Immediate Medical Attention
If symptoms persist, seek medical advice (inhalation). If symptoms develop and persist, get medical attention (skin). Get medical attention (eye, ingestion).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
In case of fire, keep containers cool with water spray.
Prevent inhalation of fumes and gases.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a partly filled, closed container until disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat, spark and flame. Do not get on skin or clothing. Avoid eye contact. Do not wear contact lenses.
Store in a dry area below 90° F. Store away from heat, sparks, flames, or other sources of ignition. Avoid exposure to light.
Do not get on skin or clothing. Avoid eye contact. Do not wear contact lenses.
Keep away from heat, spark and flame. Store away from heat, sparks, flames, or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
None under normal processing.
Heat, flames, sparks and other sources of ignition. Exposure to light.
Heat, sunlight, or UV light. Bases. Oxidizing agents. Acids.
Oxides of carbon. Oxides of silicon. Formaldehyde. Methanol is liberated slowly upon exposure to moisture.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (Isobornyl acrylate)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC?
The signal word is warning.
What is the physical form of LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC?
LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC is a liquid with yellow color. It has mild odor.
What is the solubility of LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC?
Insoluble Water
What is LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC used for?
Silicone sealant
What are the hazard statements for LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC?
This substance has 3 hazard statements:
- H227: COMBUSTIBLE LIQUID.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
What is the melting point of LOCTITE SI 5092 known as LOCTITE® 5092™ NUVA-SIL® SILIC?
The melting point is Not applicable, Product is a liquid and the boiling point is > 93 °C (> 199.4 °F).