Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G)
- Product Code
- 1430168
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Die attach adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Hazardous Component(s) | CAS Number | Weight %* |
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silica | 7631-86-9 | 60 - 80% | Yes |
| 4,4'-isopropylidenediphenol-, polymer with (chloromethyl)oxirane, acrylate | 55818-57-0 | 1 - 5% | Yes |
| Trimethylolpropane triacrylate | 15625-89-5 | 1 - 5% | Yes |
| Tert-butyl perbenzoate | 614-45-9 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Keep unnecessary personnel away.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
LOCTITE ECCOBOND FP4802 10CCMU
---
LOCTITE ECCOBOND FP4549 10MLX
---
LOCTITE ECCOBOND FP0097 30CC
---
LOCTITE ECCOBOND FP4531 10ML
---
LOCTITE ECCOBOND FP4520 30ML
---
LOCTITE ECCOBOND UF 3808 50MLX
---
LOCTITE ECCOBOND LCM 1000AF
---
LOCTITE ECCOBOND 3593 RD known as HYSOL 6oz 3593 SNP CURE UF RED
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wear suitable protective clothing, safety glasses and gloves. Keep container closed.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store in a dry place.
Wash thoroughly after handling. When using do not eat, drink or smoke.
Remove all sources of ignition. Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
High temperatures. Store away from incompatible materials. Heat, flames, sparks and other sources of ignition. Ultraviolet radiation.
Strong oxidizing agents. Strong reducing agents. Strong acids and strong bases. Free radical initiators. Amines. Copper. Copper alloys. Carbon steel. Iron.
Oxides of carbon. Oxides of nitrogen. Hydrocarbons. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3077
- Shipping Name
- Environmentally hazardous substance, solid, n.o.s. (Bismaleimide resin)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G)?
The signal word is warning.
What is the physical form of LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G)?
LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G) is a solid, paste with off white color. It has characteristic odor.
What is the solubility of LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G)?
Negligible Water; Partially miscible ketones
What is LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G) used for?
Die attach adhesive
What are the hazard statements for LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G)?
This substance has 3 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
What is the melting point of LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G)?
The melting point is Not available. and the boiling point is Not applicable, Polymerizes before boiling point is reached..