Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C
- Product Code
- EO1060-V25
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Encapsulant
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Epichlorohydrin-4,4'-isopropylidene diphenol resin | 25068-38-6 | 10 - 30% | No |
| hexahydromethylphthalic anhydride | 25550-51-0 | 10 - 30% | No |
| Substituted phthalic anhydride | 34090-76-1 | 1 - 5% | No |
| Quartz (SiO2), <1% respirable | 14808-60-7 | 1 - 5% | No |
| Acrylonitrile, polymer with 1,3-butadiene and styrene | 9003-56-9 | 1 - 5% | No |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Wash clothing before reuse. Get medical attention. Thoroughly clean shoes before reuse.
Check for and remove any contact lenses. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. If individual is conscious, wash out mouth with water. Never give anything by mouth to an unconscious person. Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Keep unnecessary personnel away. In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE ECCOBOND FP4660 known as HYSOL 30cc LOW CTE GLB AMK - 40C
---
LOCTITE ECCOBOND FP4655 known as 30CC FP4655 LWSTRESS EN/CH - 40C
---
LOCTITE ECCOBOND FP 5201 known as Hysol FP5201 (8G)
---
LOCTITE ECCOBOND FP0097 30CC
---
LOCTITE ECCOBOND FP4526 30CC
---
LOCTITE ECCOBOND EN UV9721 30CC
---
LOCTITE ECCOBOND FP4549 30CC
---
LOCTITE ECCOBOND FP4655 30CC
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wear suitable protective clothing, safety glasses and gloves. Keep container closed.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store in a dry place. Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling. When using do not eat, drink or smoke.
Remove all sources of ignition. Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Store away from incompatible materials. Heat, flames, sparks and other sources of ignition. Elevated temperatures.
Oxidizing agents. Acids. Bases. Amines.
Oxides of carbon. Oxides of nitrogen. Aldehydes. Phenolics. Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C?
The signal word is danger.
What is the physical form of LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C?
LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C is a liquid with black color. It has aromatic odor.
What is the solubility of LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C?
Insoluble Water
What is LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C used for?
Encapsulant
What are the hazard statements for LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C?
This substance has 5 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H318: CAUSES SERIOUS EYE DAMAGE.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE ECCOBOND EO1060 known as HYSOL EO1060 30CC ONE COMP -40C?
The melting point is Not available. and the boiling point is Not available..