NextSDS Logo
Safety Data Sheet EN

LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH
Product Code
1822912

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coating

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A
Skin Sens. Cat. 1
Repr. Cat. 1B

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H360 MAY DAMAGE FERTILITY OR THE UNBORN CHILD.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 If exposed or concerned: Get medical attention.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hexane, 1,6-diisocyanato-, homopolymer, 2-hydroxyethyl acrylate-blocked 264888-31-5 30 - 60% Yes
Isobornyl acrylate 5888-33-5 30 - 60% Yes
dibutyltin dilaurate 77-58-7 0.1 - 1% Yes

Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours. Extreme asthmatic reactions can be life threatening.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye contact

Flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding eyelids open all the time. Get medical attention.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get immediate medical attention.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Sealed containers at elevated temperatures or contaminated with water may rupture explosively. At higher temperatures isocyanate may be released.

Instructions

Water should be used to cool closed containers to prevent pressure build-up and possible autoignition or explosion when exposed to extreme heat.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Isolate area. Keep unnecessary personnel away.

Small spill

For minor spills, absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution

Materials: sawdust or other absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Do not taste or swallow. Protect from moisture. Keep away from heat, spark and flame.

Storage

Store between 20 °C (68°F) and 30 °C (86°F). Do not let moisture contaminate this material.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat, spark and flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use local ventilation if general ventilation is insufficient to maintain vapor concentration below established exposure limits. Standard reference sources regarding industrial ventilation (i.e., ACGIH Industrial Ventilation) should be consulted for guidance about adequate ventilation. Air monitoring: Monitoring of airborne isocyanates in the breathing zone of individuals should become part of the overall employee exposure characterization program. Isocyanate exposure levels must be monitored. Monitoring techniques have been developed by NIOSH and OSHA. Medical Surveillance: Medical supervision of all employees who handle or come in contact with isocyanates is recommended. Persons with asthmatic-type conditions, chronic bronchitis, other chronic respiratory diseases or recurrent skin eczema or sensitization should be excluded from working with isocyanates. Once a person is diagnosed as sensitized to an isocyanate, no further exposure can be permitted.

Hands

Permeation resistant gloves (butyl rubber, nitrile rubber, polyvinyl alcohol). However, please note that polyvinyl alcohol degrades in water.

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists.

Respiratory

A positive pressure, supplied-air respirator or a self-contained breathing apparatus is recommended when: airborne concentrations of isocyanate are known to exceed 0.005 ppm; operations are performed in a confined space or area with limited ventilation; material is heated or sprayed. Observe OSHA regulations for respirator use (29 CFR 1910.134).

Skin/Body

Cover as much of the exposed skin area as possible with appropriate clothing. If skin creams are used, keep the area covered by the cream to a minimum.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
> 20.5 mm2/s
Odor
Acrylate
Appearance
---
Freezing Point
---
Evaporation Rate
Not available.
State Under Standard Conditions
---
Solubility In Water
---
Ph
Not applicable, Product is non-soluble (in water).
Solidification Point
---
Flammability
The product is not flammable.
Voc Content
< 1 %; < 10 g/l (value for resin and hardener together) (estimated)
Form
---
Melting Point
Not applicable, Product is a liquid
Colour Intensity
---
Auto Ignition Temperature
Not available.
Relative Evaporation Rate
---
Dynamic Viscosity
<= 0.1 mPa.s
Molecular Weight
---
Vapor Density
---
Crystallisation Point
---
Softening Point
---
Density
1.1
Vapor Pressure
< 1 hPa (20 °C (68°F))
Metal Corrosion
---
Solubility In Fat
---
Partition Coefficient
Not available.
Cloud Point
---
Explosive Limits
---
Physical State
Liquid
Lower Explosive Limit
Not available.
Physical State Data
liquid
Relative Density
---
Flash Point
> 93 °C (> 199.4 °F)
Boiling Point
> 100 °C (> 212°F)
Decomposition Temperature
Not available.
Solubility
Not miscible or difficult to mix Water
Odor Threshold
Not available.
Properties Status
---
Colour
Colorless / Colorless
Bulk Density
---
Upper Explosive Limit
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Contact with moisture, other materials that react with isocyanates, or temperatures above 350°F (177° C), may cause polymerization.

Avoid

Keep away from heat, spark and flame. High temperatures. Contamination with water. Store away from incompatible materials. UV light. Direct sunlight.

Incompatible

Strong oxidizing agents. Water, Amines, Alkalis, Alcohols. Will cause some corrosion of copper alloys and aluminum. Peroxides.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors. Hydrogen cyanide. Isocyanate vapors Oxides of carbon. Oxides of nitrogen.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
Environmentally hazardous substance, liquid, n.o.s. (Isobornyl acrylate)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH?

The signal word is danger.

What is the physical form of LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH?

LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH is a liquid with colorless / colorless color. It has acrylate odor.

What is the solubility of LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH?

Not miscible or difficult to mix Water

What is LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH used for?

Coating

What are the hazard statements for LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH?

This substance has 4 hazard statements:

  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H360: MAY DAMAGE FERTILITY OR THE UNBORN CHILD.

What is the melting point of LOCTITE STYCAST PC 40UMF known as HYSOL PC40-UM-F 10ML EN/CH?

The melting point is Not applicable, Product is a liquid and the boiling point is > 100 °C (> 212°F).