Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Loctite Power Grab All Purpose Express
- Product Code
- 2029846
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive, water-based
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
CHEMTREC
1-703-527-3887
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Limestone | 1317-65-3 | 30 - 60% | Yes |
| Quartz (SiO2), <1% respirable | 14808-60-7 | 0.1 - 1% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms persist, seek medical advice.
Wash affected area immediately with soap and water. If symptoms develop and persist, get medical attention.
In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
Rinse out mouth. Do not drink. Never give anything by mouth to an unconscious person. If adverse health effects develop seek medical attention.
Immediate Medical Attention
Seek immediate medical attention for eye contact. If symptoms persist for inhalation, skin contact, or ingestion, seek medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard.
Water may be unsuitable as an extinguishing media, but may be helpful in keeping adjacent containers cool.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Ventilate area. Do not allow product to enter sewer or waterways.
Absorb spill with inert material. Shovel material into appropriate container for disposal. Wear appropriate protective equipment and clothing during clean-up.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes. Avoid prolonged or repeated skin contact with this material. Use only with adequate ventilation. Wash hands before breaks and immediately after handling the product. Keep out of the reach of children.
Keep from freezing.
Wash hands before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Will not occur.
Freezing conditions.
This product may react with strong acids, bases and oxidizing agents.
Carbon dioxide. Carbon monoxide. Oxides of nitrogen. Hydrocarbons.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Loctite Power Grab All Purpose Express?
The signal word is warning.
What is the physical form of Loctite Power Grab All Purpose Express?
Loctite Power Grab All Purpose Express is a liquid with white color. It has not available. odor.
What is the solubility of Loctite Power Grab All Purpose Express?
Soluble
What is Loctite Power Grab All Purpose Express used for?
Adhesive, water-based
What are the hazard statements for Loctite Power Grab All Purpose Express?
This substance has 1 hazard statement:
- H320: CAUSES EYE IRRITATION.
What is the melting point of Loctite Power Grab All Purpose Express?
The melting point is Not available. and the boiling point is > 100 °C (> 212°F).